SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:a80db21c-5996-4c7d-a7d4-e56444a52b6b"
 

Search: id:"swepub:oai:lup.lub.lu.se:a80db21c-5996-4c7d-a7d4-e56444a52b6b" > Capacity Degradatio...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Capacity Degradation with Modeling Hardware Impairment in Large Intelligent Surface

Hu, Sha (author)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
Rusek, Fredrik (author)
Lund University,Lunds universitet,Kommunikationsteknologi,Forskargrupper vid Lunds universitet,Communications Engineering,Lund University Research Groups
Edfors, Ove (author)
Lund University,Lunds universitet,Kommunikationsteknologi,Forskargrupper vid Lunds universitet,Communications Engineering,Lund University Research Groups
 (creator_code:org_t)
2019
2019
English.
In: 2018 IEEE Global Communications Conference, GLOBECOM 2018 - Proceedings. - 9781538647271
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • In this paper, we consider capacity degradations stemming from potential hardware impairments (HWI) of newly proposed Large Intelligent Surface (LIS) systems. Without HWI, the utility of surface-area (the first-order derivative of the capacity with respect to surface-area) is shown to be proportional to the inverse of it. With HWI, the capacity as well as the utility of surface-area are both degraded, due to a higher effective noise level caused by the HWI. After first modeling the HWI in a general form, we derive the effective noise density and the decrement of utility in closed-forms. With those the impacts of increasing the surface-area can be clearly seen. One interesting but also natural outcome is that both the capacity and utility can be decreased when increasing the surface-area in the cases with severe HWI. The turning points where the capacity and the utility start to decrease with HWI can be evaluated from the derived formulas for them. Further, we also consider distributed implementations of a LIS system by splitting it into multiple small LIS-Units, where the impacts of HWI can be significantly suppressed due to a smaller surface-area of each unit.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Kommunikationssystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Communication Systems (hsv//eng)

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Hu, Sha
Rusek, Fredrik
Edfors, Ove
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
and Communication Sy ...
Articles in the publication
2018 IEEE Global ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view