Development and validation of a quantitative wipe sampling method to determine platinum contamination from antineoplastic drugs on surfaces in workplaces at Swedish hospitals

Leeman, Mats (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine,Region Skåne
Wetterling, Maria (författare)
Region Skåne
Kåredal, Monica (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Genetisk arbets- och miljömedicin,Forskargrupper vid Lunds universitet,LTH profilområde: Aerosoler,LTH profilområden,LTH profilområde: Nanovetenskap och halvledarteknologi,LU profilområde: Ljus och material,Lunds universitets profilområden,Other operations, LTH,Faculty of Engineering, LTH,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine,Genetic Occupational and Environmental Medicine,Lund University Research Groups,LTH Profile Area: Aerosols,LTH Profile areas,Faculty of Engineering, LTH,LTH Profile Area: Nanoscience and Semiconductor Technology,Faculty of Engineering, LTH,LU Profile Area: Light and Materials,Lund University Profile areas,Region Skåne
visa fler...
Hedmer, Maria (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Tillämpad masspektrometri inom miljömedicin,Forskargrupper vid Lunds universitet,LTH profilområde: Aerosoler,LTH profilområden,LTH profilområde: Nanovetenskap och halvledarteknologi,LU profilområde: Ljus och material,Lunds universitets profilområden,Other operations, LTH,Faculty of Engineering, LTH,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine,Applied Mass Spectrometry in Environmental Medicine,Lund University Research Groups,LTH Profile Area: Aerosols,LTH Profile areas,Faculty of Engineering, LTH,LTH Profile Area: Nanoscience and Semiconductor Technology,Faculty of Engineering, LTH,LU Profile Area: Light and Materials,Lund University Profile areas,Region Skåne
visa färre...
 (creator_code:org_t)
Engelska.
Ingår i: Journal of oncology pharmacy practice. - 1078-1552.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • INTRODUCTION: Antineoplastic drugs (ADs) are frequently used pharmaceuticals in the healthcare, and healthcare workers can be occupationally exposed to ADs. Monitoring of surface contamination is a common way to assess occupational exposure to ADs. The objective was to develop and validate a sensitive and quantitative monitoring method to determine surface contaminations of Pt as a marker for Pt-containing ADs. The surface contaminations of Pt-containing ADs were monitored at four Swedish hospital workplaces.METHODS: An analytical method was developed based on inductively coupled plasma mass spectrometry. The wipe sampling procedure was validated regarding different surface materials. The stability of collected wipe samples was investigated. Workplace surfaces were monitored by wipe sampling to determine contaminations of Pt-containing ADs.RESULTS: A wipe sampling and analytical method with a limit of detection of 0.1 pg Pt/cm 2 was developed. Pt was detected in 67% of the wipe samples collected from four workplaces, and the concentrations ranged from <0.10 to 21100 pg/cm 2. In 4% of samples, the detected surface contaminations of Pt in three hospital wards were above proposed hygienic guidance value (HGV) of Pt. In the hospital pharmacy, 9% of the detected surface contaminations of Pt were above lowest proposed HGV. CONCLUSIONS: A user-friendly, specific, and sensitive method for determination of surface contaminations of Pt from ADs in work environments was developed and validated. A large variation of contaminations was observed between detected surface contaminations of Pt in samples collected in wards, and it likely reflects differences in amounts handled and work practices between the wards.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Leeman, Mats
Wetterling, Mari ...
Kåredal, Monica
Hedmer, Maria
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Arbetsmedicin oc ...
Artiklar i publikationen
Journal of oncol ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy