Sökning: id:"swepub:oai:lup.lub.lu.se:b0a316bb-8ca0-43f7-acca-d5bd988f377c" >
Estimation of arter...
Estimation of arterial pulse wave velocity with a new improved tissue Doppler method
-
- Cinthio, Magnus (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Eriksson, Anders (författare)
- Lund University: LTH
-
- Persson, Hans W (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
visa fler...
-
- Lindström, Kjell (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 2001
- 2001
- Engelska 4 s.
-
Ingår i: 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society. - 0780372115 ; , s. 188-191
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The mechanical properties of the large arteries are important determinants in the circulation physiology. Quantities associated with vessel wall elasticity are of particular interest since they offer a possibility to separate diseased arteries from healthy. Pulse wave velocity (PWV) is a local measure of the arterial wall elasticity. This paper describes a new improved method for non-invasive local PWV estimation. The PWV estimation is based on arterial wall movements, which is detected by Tissue Doppler Imaging (TDI), a color Doppler optimized for low velocities. The TDI facility allows the artery to be measured at several positions simultaneously, which improves the PWV estimation considerably. The method is validated with respect to operator repeatability and operator reproducibility in a limited clinical study.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
Publikations- och innehållstyp
- kon (ämneskategori)
- vet (ämneskategori)
Hitta via bibliotek
Till lärosätets databas