SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:b35aed0c-d2d4-4709-85a7-3d95c3545fc4"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:b35aed0c-d2d4-4709-85a7-3d95c3545fc4" > Mapping prostatic m...

Mapping prostatic microscopic anisotropy using linear and spherical b-tensor encoding : A preliminary study

Nilsson, Markus (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Multidimensional microstructure imaging,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments
Eklund, Greta (författare)
Random Walk Imaging AB
Szczepankiewicz, Filip (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,MR Physics,Forskargrupper vid Lunds universitet,Multidimensional microstructure imaging,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
visa fler...
Skorpil, Mikael (författare)
Karolinska Institutet,Karolinska Institute,Karolinska University Hospital
Bryskhe, Karin (författare)
Random Walk Imaging AB
Westin, Carl Fredrik (författare)
Harvard Medical School
Lindh, Claes (författare)
Karolinska Institute
Blomqvist, Lennart (författare)
Karolinska Institutet,Karolinska Institute,Karolinska University Hospital
Jäderling, Fredrik (författare)
Karolinska Institutet,Karolinska Institute,Capio St. Görans Sjukhus,Karolinska University Hospital
visa färre...
 (creator_code:org_t)
2021-05-31
2021
Engelska 9 s.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 86:4, s. 2025-2033
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: Tensor-valued diffusion encoding provides more specific information than conventional diffusion-weighted imaging (DWI), but has mainly been applied in neuroimaging studies. This study aimed to assess its potential for the imaging of prostate cancer (PCa). Methods: Seventeen patients with histologically proven PCa were enrolled. DWI of the prostate was performed with linear and spherical tensor encoding using a maximal b-value of 1.5 ms/µm2 and a voxel size of 3 × 3 × 4 mm3. The gamma-distribution model was used to estimate the mean diffusivity (MD), the isotropic kurtosis (MKI), and the anisotropic kurtosis (MKA). Regions of interest were placed in MR-defined cancerous tissues, as well as in apparently healthy tissues in the peripheral and transitional zones (PZs and TZs). Results: DWI with linear and spherical encoding yielded different image contrasts at high b-values, which enabled the estimation of MKA and MKI. Compared with healthy tissue (PZs and TZs combined) the cancers displayed a significantly lower MD (P <.05), higher MKI (P < 10−5), and lower MKA (P <.05). Compared with the TZ, tissue in the PZ showed lower MD (P < 10−3) and higher MKA (P < 10−3). No significant differences were found between cancers of different Gleason scores, possibly because of the limited sample size. Conclusion: Tensor-valued diffusion encoding enabled mapping of MKA and MKI in the prostate. The elevated MKI in PCa compared with normal tissues suggests an elevated heterogeneity in the cancers. Increased in-plane resolution could improve tumor delineation in future studies.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

diffusion-weighted imaging
heterogeneity
microscopic anisotropy
prostate cancer
tensor-valued diffusion encoding

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy