Sökning: id:"swepub:oai:lup.lub.lu.se:b3a0ed98-4e89-4822-8cd3-6bf3f0b73449" >
Computer simulation...
Computer simulation analysis of source-detector position for percutaneously measured O2-gas signal in a three-dimensional preterm infant lung
-
- Liao, Peilang (författare)
- GPX Medical AB,Lund University
-
- Larsson, Jim (författare)
- Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
- Krite Svanberg, Emilie (författare)
- Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
-
visa fler...
-
- Lundin, Patrik (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
- Swartling, Johannes (författare)
- GPX Medical AB
-
- Lewander Xu, Märta (författare)
- GPX Medical AB
-
- Bood, Joakim (författare)
- Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
- Andersson-Engels, Stefan (författare)
- Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH,Tyndall National Institute,University College Cork
-
visa färre...
-
(creator_code:org_t)
- 2018-07-31
- 2018
- Engelska.
-
Ingår i: Journal of Biophotonics. - : Wiley. - 1864-063X. ; 11:11
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Further improvements in the clinical care of our most vulnerable patients-preterm infants-are needed. Novel diagnostic and surveillance tools facilitate such advances. The GASMAS technique has shown potential to become a tool to, noninvasively, monitor gas in the lungs of preterm infants, by placing a laser source and a detector on the chest wall skin. It is believed that this technology will become a valuable clinical diagnostic tool for monitoring the lung function of these patients. Today, the technology is, for this application, in an early stage and further investigations are needed. In the present study, a three-dimensional computer model of the thorax of an infant is constructed, from a set of CT images. Light transport simulations are performed to provide information about the position dependence of the laser- and detector probe on the thorax of the infant. The result of the simulations, based on the study method and the specified model used in this work, indicates that measurement geometries in front and on the side of the lung are favorable in order to obtain a good gas absorption signal.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)
Nyckelord
- Computational phantom
- Light transport simulation
- Preterm infants
- Respiratory distress syndrome
- Tunable diode laser absorption spectroscopy
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas