SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:b3a0ed98-4e89-4822-8cd3-6bf3f0b73449"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:b3a0ed98-4e89-4822-8cd3-6bf3f0b73449" > Computer simulation...

Computer simulation analysis of source-detector position for percutaneously measured O2-gas signal in a three-dimensional preterm infant lung

Liao, Peilang (författare)
GPX Medical AB,Lund University
Larsson, Jim (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Krite Svanberg, Emilie (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
visa fler...
Lundin, Patrik (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Swartling, Johannes (författare)
GPX Medical AB
Lewander Xu, Märta (författare)
GPX Medical AB
Bood, Joakim (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Andersson-Engels, Stefan (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH,Tyndall National Institute,University College Cork
visa färre...
 (creator_code:org_t)
2018-07-31
2018
Engelska.
Ingår i: Journal of Biophotonics. - : Wiley. - 1864-063X. ; 11:11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Further improvements in the clinical care of our most vulnerable patients-preterm infants-are needed. Novel diagnostic and surveillance tools facilitate such advances. The GASMAS technique has shown potential to become a tool to, noninvasively, monitor gas in the lungs of preterm infants, by placing a laser source and a detector on the chest wall skin. It is believed that this technology will become a valuable clinical diagnostic tool for monitoring the lung function of these patients. Today, the technology is, for this application, in an early stage and further investigations are needed. In the present study, a three-dimensional computer model of the thorax of an infant is constructed, from a set of CT images. Light transport simulations are performed to provide information about the position dependence of the laser- and detector probe on the thorax of the infant. The result of the simulations, based on the study method and the specified model used in this work, indicates that measurement geometries in front and on the side of the lung are favorable in order to obtain a good gas absorption signal.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)

Nyckelord

Computational phantom
Light transport simulation
Preterm infants
Respiratory distress syndrome
Tunable diode laser absorption spectroscopy

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy