Calculation and measurements of absorbed dose in total body irradiation

Svahn-Tapper, Gudrun (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Nilsson, Per (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Jönsson, Christel (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
visa fler...
Alvegård, Thor (författare)
Lund University,Lunds universitet,Medicinsk onkologi,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical oncology,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2009-07-08
1990
Engelska.
Ingår i: Acta Oncologica. - : Informa UK Limited. - 1651-226X .- 0284-186X. ; 29:5, s. 627-633
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A method which is simple, reliable, and rapid to use in clinical routine for basic dose calculation in total body irradiation (TBI) has been tested with 8 MV x-rays. The dosimetry follows, as far as possible, national and international recommendations for conventional radiotherapy. The dose rate at different locations and depths is calculated from the absorbed dose rate at dose maximum for a phantom size of 30 x 30 x 30 cm in the TBI field (Dc), an inverse square law factor (SAD2/SPD2), the tissue-maximum ratio (TMR), an equivalent phantom and patient size correction factor (A), a factor for lack of back-scattering material (B), an off-axis output correction factor (O), and a factor that corrects for off-axis variations in effective photon beam energy and for oblique beam penetration of the patient (R). The collimator opening is constant for all patient sizes. It is shown that TMR, A, B and R can be measured in conventional geometry in ordinary phantoms but at an extended distance, while Dc, O and SAD2/SPD2 must be measured in TBI geometry. Tests in Humanoid phantoms showed an agreement in measured and planned AP/2 doses of 2% or better. If the calculation method is used for lower photon energies or in other TBI geometries it may be necessary to correct for the elliptical shape of the patient and for back-scattered radiation from the walls or floor.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

leukaemia
8 MV x-rays
radiotherapy
Total body irradiation
dosimetry
bone marrow transplantation

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Svahn-Tapper, Gu ...
Nilsson, Per
Jönsson, Christe ...
Alvegård, Thor
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Cancer och onkol ...
Artiklar i publikationen
Acta Oncologica
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy