SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:bc389bde-cb36-4edf-a010-8c6a84228c2d"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:bc389bde-cb36-4edf-a010-8c6a84228c2d" > The influence of 13...

The influence of 134Cs on the 137Cs gamma-spectrometric peak-to-valley ratio and improvement of the peak-to-valley method by limiting the detector field of view

Östlund, Karl (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Samuelsson, Christer (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Mattsson, Sören (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa fler...
Rääf, Christopher L. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
Elsevier BV, 2017
2017
Engelska 7 s.
Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043. ; 128, s. 249-255
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The peak-to-valley method was investigated under laboratory conditions and in situ with respect to both 134Cs perturbation of the 137Cs valley and use of collimation. The 134Cs perturbation is significant down to 134Cs:137Cs activity ratios of 1:100. In these cases the full energy peaks from 134Cs (796 and 802 keV) and associated valley should be used instead of the peak and valley from the 137Cs 662 keV peak. Use of collimators in situ outside Fukushima Daiichi significantly increased PTV for 134Cs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Cs and Cs deposition
Collimators
Depth distribution
Field gamma spectrometry
Fukushima
HPGe
in situ
Peak-to-valley ratio
PTV

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Östlund, Karl
Samuelsson, Chri ...
Mattsson, Sören
Rääf, Christophe ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Applied Radiatio ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy