SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:bcdad597-5e26-4cc5-8afc-046ba0e4b2ca"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:bcdad597-5e26-4cc5-8afc-046ba0e4b2ca" > The relative accura...

The relative accuracies of ECG precordial lead waveforms derived from EASI leads and those acquired from paramedic applied standard leads

Sejersten, M (författare)
Pahlm, Olle (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Pettersson, Jonas (författare)
Lund University,Lunds universitet,Avdelningen för klinisk genetik,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Clinical Genetics,Department of Laboratory Medicine,Faculty of Medicine
visa fler...
Clemmensen, PM (författare)
Rautaharju, F (författare)
Zhou, O (författare)
Maynard, C (författare)
Feldman, CL (författare)
Wagner, GS (författare)
visa färre...
 (creator_code:org_t)
2003
2003
Engelska.
Ingår i: Journal of Electrocardiology. - 1532-8430. ; 36:3, s. 179-185
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Accurate precordial electrode placement can be difficult in emergency situations leading either to loss of time or diminished accuracy. A possible solution is the quasi-orthogonal EASI lead system, with only five electrodes and easily defined landmarks to provide a derived 12-lead electrocardiogram (ECG). The purpose of this study was to test the hypothesis that precordial waveforms in EASI-derived ECGs have no greater deviation from those in gold standard ECGs, than do the precordial waveforms in paramedic acquired standard ECGs. Twenty paramedics applied the standard precordial electrodes employing the routine procedure. A certified ECG technician applied the 6 standard precordial electrodes in their correct gold standard positions, and the EASI electrodes. 12-lead ECGs were obtained from the paramedics' standard leads, and derived from the EASI leads, for comparison with the gold standard ECG. In each precordial lead recording, 6 computer-measured QRS-T waveform parameters were considered. Differences between DeltaEASI-gold standard versus Deltaparamedic-gold standard were calculated for every waveform in every lead resulting in 720 comparisons. EASI and paramedic results were "equally accurate" in 47%, the paramedic was more accurate in 31%, and EASI was more accurate in the remaining 22%. The differences from gold standard recording of precordial waveforms in ECGs derived from the EASI leads and those acquired via paramedic-applied standard electrodes are similar. The results suggest that the EASI lead system may provide an alternative,to the standard ECG precordial leads to facilitate data acquisition and possibly save valuable time in emergency situations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

prehospital ECG
EASI lead system

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy