SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:bfd0c6bc-be65-43d8-b9e4-aa1cf130f504"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:bfd0c6bc-be65-43d8-b9e4-aa1cf130f504" > Single-cell dosimet...

Single-cell dosimetry for radioimmunotherapy of B-cell lymphoma patients with special reference to leukemic spread

Hindorf, Cecilia (författare)
Lund University,Lunds universitet,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Emfietzoglou, Dimitris (författare)
Lindén, Ola (författare)
Lund University,Lunds universitet,Bröstcancer-genetik,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Breastcancer-genetics,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Bousis, Christos (författare)
Fotopoulos, Andreas (författare)
Kostarelos, Kostas (författare)
Flux, Glenn D. (författare)
visa färre...
 (creator_code:org_t)
Mary Ann Liebert Inc, 2007
2007
Engelska.
Ingår i: Cancer Biotherapy & Radiopharmaceuticals. - : Mary Ann Liebert Inc. - 1557-8852 .- 1084-9785. ; 22:3, s. 357-366
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Aims: Many lymphoma patients have both macroscopic tumors and single-cell manifestations of their disease. Treatment efficacy could, therefore, depend on the radionuclide used. The aim of this study was to investigate dosimetry at a cellular level for three isotopes of radioiodine. Methods: Cells were assumed to be spherical with radii of 6.35, 7.7, and 9.05 mu m corresponding to the dimensions of the Raji cells. The radius of the nucleus was assumed to be 75% of the cellular radius. The electron energies were 18, 28, and 190 keV, corresponding to the mean electron energy per decay for I-125, I-123, and I-131, respectively. S-values for different activity distributions were simulated using Monte Carlo and dose-volume histograms as well as absorbed doses, and absorbed dose rates were calculated. Results: I-125 gives the highest absorbed dose (similar to 4-40 times that of I-131), whereas I-123 Will give the highest absorbed dose rate (similar to 100 times that of I-131). Under the given assumptions, the absorbed dose at this level is more dependent on the Size of the cells than on whether the radioimmunoconjugate is internalized. Conclusions: This enquiry showed that both I-123 and I-125 have greater potential than I-131 for the treatment of leukemic spread in patients With lymphoma.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

single cells
dosimetry
lymphoma

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy