SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:c0905344-c05a-4e2f-b2fa-f67c632086be"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:c0905344-c05a-4e2f-b2fa-f67c632086be" > Acoustic Differenti...

Acoustic Differential Extraction - ultrasonic DNA-extraction from sexual assault evidence

Evander, Mikael (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Horsman, Katie M. (författare)
Easley, Christopher J. (författare)
visa fler...
Landers, James P. (författare)
Laurell, Thomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Nilsson, Johan (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Benes, Ewald (redaktör/utgivare)
visa färre...
 (creator_code:org_t)
2007
2007
Engelska 1 s.
Ingår i: International Congress on Ultrasonics. ; 1, s. 151-151
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Isolation of the male and female DNA is one of the most important steps in obtaining the DNA profile of the perpetrator in sexual assault cases. The sample is obtained by taking a vaginal swab containing both epithelial cells from the female and sperm cells from the male from the victim. The purity of the extracted male fraction decides whether or not a single-source DNA profile of the suspect will be obtained or not. The existing techniques are have poor separation efficiency, time-consuming, labour-intensive and are neither easily automated nor integrated with further analysis steps. A novel method of DNA extraction based on ultrasonic trapping, Acoustic Differential Extraction, has been developed. A microfluidic device using laminar flow valving and miniature PZT transducers retains the sperm cells while mobilizing the female fraction into a separate outlet. The device was evaluated using a mock sexual assault sample and the separated fractions were analyzed using quantitative PCR and STR-profiling. A 16-fold enrichment of the male fraction, making an originally hard-to-detect-male DNA profile readily profiled, has been demonstrated. The STR-profiling of the male and female fractions showed a male fraction purity of up to 99 % making it possible to obtain a single-source DNA-profile of the suspect. The microfluidic format of the device makes it possible to downscale the sample time from 4-8 hours to 10 minutes. It is also possible to integrate this method with further downstream analysis steps necessarey for the full forensic DNA analysis.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Publikations- och innehållstyp