SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:c4485742-50f8-475a-bd86-33ad7e2ded89"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:c4485742-50f8-475a-bd86-33ad7e2ded89" > Comparison of heart...

Comparison of heart rate measured by Polar RS 400 and ECG, validity and repeatability .

Engström, E (författare)
Ottosson, E (författare)
Wohlfart, Björn (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Grundström, N (författare)
Wisén, Anita (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: Advances in Physiotherapy. - 1651-1948. ; 14:3, s. 115-122
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Aims: The purpose of this study was to investigate criterion-related validity and test–retest repeatability of the heart rate monitor Polar RS400 versus electrocardiogram (ECG). Methodology: Ten healthy subjects, 19–34 years, performed a cycle ergometer test 5 min on each load (50, 100 and 150 W). Heart rate (HR) was measured with ECG and Polar RS400 and recorded digitally. After at least one hour resting the test was repeated. Major findings: The results showed a significant correlation between HR measured by ECG and by Polar RS400 with correlation coefficients ranging from 0.97 to 1.00. In test 1 the mean difference ± 2SD between HR Polar and HR ECG was 0.7 ± 4.3 bpm and in test 2, 0.2 ± 3.2 bpm. In the repeated tests, the mean difference of HR between test 2 and test 1 ± 2SD was 3.2 ± 11.9 bpm with ECG and 2.6 ± 14.3 bpm with Polar RS400 and these differences were not statistically significant. Conclusion: This study indicates good criterion-related validity and test–retest repeatability of Polar RS400. Differences observed at individual levels should be noticed, but are not considered to be clinically important. Polar RS400 is thus well suited for recording HR during physical activity and exercise training.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

ergometer test
exercise
heart rate monitoring
physiotherapy
submaximal activity

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Engström, E
Ottosson, E
Wohlfart, Björn
Grundström, N
Wisén, Anita
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Advances in Phys ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy