Comparison of four scatter correction methods using Monte Carlo simulated source distributions

Ljungberg, Michael (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
King, Michael A (författare)
Hademenos, George J (författare)
visa fler...
Strand, Sven-Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
1994
1994
Engelska.
Ingår i: Journal of Nuclear Medicine. - 0161-5505. ; 35:1, s. 143-151
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Scatter correction in SPECT is important for improving image quality, boundary detection and the quantification of activity in different regions. This paper presents a comparison of four scatter correction methods, three using more than one energy window and one convolution-subtraction correction method using spatial variant scatter line-spread functions. METHODS: The comparison is based on Monte Carlo simulated data for point sources on- and off-axis, hot and cold spheres of different diameters, and a clinically realistic source distribution simulating brain imaging. All studies were made for a uniform cylindrical water phantom. Since the nature of the detected photon is known with Monte Carlo simulation, separate images of primary and scattered photons can be recorded. These can then be compared with estimated scatter and primary images obtained from the different scatter correction methods. The criteria for comparison were the normalized mean square error, scatter fraction, % recovery and image contrast. RESULTS: All correction methods significantly improved image quality and quantification compared to those obtained with no correction. Quantitatively, no single method was observed to be the best by all criteria for all the source distributions. Three of the methods were observed to perform the best by at least one of the criteria for one of the source distributions. For brain imaging, the differences between all the methods were much less than the difference between them and no correction at all. CONCLUSION: It is concluded that performing scatter correction is essential for accurate quantification, and that all four methods yield a good, but not perfect, scatter correction. Since it is hard to distinguish the methods consistently in terms of their performance, it may be that the choice should be made on the basis of ease of implementation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Monte Carlo simulated data
brain imaging
SPECT
scatter correction

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy