Monte Carlo simulation of breast tomosynthesis: visibility of microcalcifications at different acquisition schemes

Petersson, Hannie (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Dustler, Magnus (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Tingberg, Anders (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa fler...
Timberg, Pontus (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
SPIE, 2015
2015
Engelska.
Ingår i: Medical Imaging 2015: Physics of Medical Imaging. - : SPIE. - 0277-786X .- 1996-756X. ; 9412, s. 94121-94121
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Microcalcifications are one feature of interest in mammography and breast tomosynthesis (BT). To achieve optimal conditions for detection of microcalcifications in BT imaging, different acquisition geometries should be evaluated. The purpose of this work was to investigate the influence of acquisition schemes with different angular ranges, projection distributions and dose distributions on the visibility of microcalcifications in reconstructed BT volumes. Microcalcifications were inserted randomly in a high resolution software phantom and a simulation procedure was used to model a MAMMOMAT Inspiration BT system. The simulation procedure was based on analytical ray tracing to produce primary images, Monte Carlo to simulate scatter contributions and flatfield image acquisitions to model system characteristics. Image volumes were reconstructed using the novel method super-resolution reconstruction with statistical artifact reduction (SRSAR). For comparison purposes, the volume of the standard acquisition scheme (50 degrees angular range and uniform projection and dose distribution) was also reconstructed using standard filtered backprojection (FBP). To compare the visibility and depth resolution of the microcalcifications, signal difference to noise ratio (SDNR) and artifact spread function width (ASFW) were calculated. The acquisition schemes with very high central dose yielded significantly lower SDNR than the schemes with more uniform dose distributions. The ASFW was found to decrease (meaning an increase in depth resolution) with wider angular range. In conclusion, none of the evaluated acquisition schemes were found to yield higher SDNR or depth resolution for the simulated microcalcifications than the standard acquisition scheme.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

breast tomosynthesis
Monte Carlo simulation
acquisition parameters
software breast phantom
microcalcification simulation

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Petersson, Hanni ...
Dustler, Magnus
Tingberg, Anders
Timberg, Pontus
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Medical Imaging ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy