SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:c755a51f-e5fa-407c-9c72-47839bf50298"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:c755a51f-e5fa-407c-9c72-47839bf50298" > Response patterns i...

Response patterns in finger and central body skin temperatures under mild whole body cooling

Vanggaard, Leif (författare)
Kuklane, Kalev (författare)
Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
Smolander, Juhani (författare)
visa fler...
Holmér, Ingvar (författare)
Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
Kounalakis, Stylianos (redaktör/utgivare)
Koskolou, Maria (redaktör/utgivare)
visa färre...
 (creator_code:org_t)
2011
2011
Engelska 4 s.
Ingår i: Environmental Ergonomics. ; XIV, s. 124-127
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • INTRODUCTION The actual heat loss may be underestimated especially in studies employing mild whole-body cooling, if AVA-rich distal areas are not taken into account. In the present report, we illustrate the skin temperature response pattern in fingers (rich in AVAs) to transient whole-body cooling as compared to non-acral body sites (without AVAs). METHODS Eight men participated in the study. During the test the subjects were dressed in shorts, socks and shoes and stayed seated with the arms on insulated supports at heart level. The air temperature of 32 °C was after 25 minutes gradually reduced to 13 °C (0.2 °C/min). Core, finger (sulcus lateral to the nailbed) and non-acral skin (8 points) temperatures were measured. RESULTS During cooling the mean skin temperature in all subjects decreased at a similar rate. Higher variation in the end of the cooling could be explained by differences in body fat (R2=0.902). Simultaneously, the finger cooling could start with up to about 1 hour difference in different subjects. DISCUSSION AND CONCLUSION Mean skin temperature did not give any idea on when the subjects left thermal neutrality. It is strongly recommended to measure finger (or toe) temperatures when maintaining the thermal comfort of the subjects in dynamic conditions is important.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Vanggaard, Leif
Kuklane, Kalev
Smolander, Juhan ...
Holmér, Ingvar
Kounalakis, Styl ...
Koskolou, Maria
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Produktionstekni ...
Artiklar i publikationen
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy