Sökning: id:"swepub:oai:lup.lub.lu.se:ca77edb8-9923-43d0-80c7-0181cd633ccf" >
Water uptake and re...
Water uptake and release from iodine-containing bone cement.
-
- Kjellson, Fred (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Brudeli, B. (författare)
-
- McCarthy, Ian (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa fler...
-
- Lidgren, Lars (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- 2004
- 2004
- Engelska.
-
Ingår i: Journal of Biomedical Materials Research. Part A. - : Wiley. - 1552-4965 .- 0021-9304 .- 1097-4636. ; 71:2, s. 292-298
- Relaterad länk:
-
http://www.ncbi.nlm....
-
visa fler...
-
http://dx.doi.org/10...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Water uptake and release characteristics of PMMA cement containing the water-soluble contrast media iohexol or iodixanol have been investigated. The water uptake study revealed that iohexol had the highest uptake of water (3.7%) and that iodixanol had an uptake close to that of Palacos(R) R (2.3% and 1.9%). The curves obtained showed the materials to follow classic diffusion theory, with an initial linearity with respect to t(1/2) making it possible to calculate the diffusion coefficients. This showed iohexol to have the lowest diffusion coefficient, Palacos(R) R the highest, and iodixanol close to that of Palacos(R) R. The release study showed that more iohexol than iodixanol was released from the bone cement; the long-term release was above 25 mug/ml, for iohexol compared to slightly above 10 mug/mL for iodixanol. A muCT investigation showed that the risk of developing an observable radiolucent zone is negligible. (C) 2004 Wiley Periodicals, Inc.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
Nyckelord
- water uptake
- water
- release
- poly(methyl methacrylate)
- absorption characteristics
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas