Application of heat pump systems for energy conservation in paper drying

Abrahamsson, K (författare)
Stenström, Stig (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Aly, Gharib (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Jernqvist, Åke (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
1997
1997
Engelska.
Ingår i: International Journal of Energy Research. - 0363-907X. ; 21:7, s. 631-642
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Drying is one of the most energy intensive and common operations in the chemical and process industries. Scope for energy recovery is substantial, particularly from the latent heat of the exhaust moist air. Using real operating data from a major Swedish mill, optimal energy conservation strategies were investigated using different heat pump systems in paper drying. Simulation results are compared for compressor-driven and absorption heat pump systems. An absorption heat transformer was also investigated. A CH3OH-LiBr double-lift cycle would have a low COP value due to the low temperature of the moist air stream and the restricted temperature of the cooling water available. A total of 30 MW thermal equivalent is currently needed in the mill at a temperature of 75 degrees C for mixing-pits, district heating and a log store. Exhaust humid air at a temperature of 54 degrees C from only three of the paper machines was used in this study. SHPUMP simulations revealed that installing a mechanical heat pump unit using HFC 134a would result in a recovery of 22 MW due to the temperature level of this application. On the other hand, 12 MW can be recovered with an absorption heat pump. To optimize the operating conditions, H2O-NaOH was selected as the best of three based on exergy index criteria. Assuming a steam cost of 22 $/MW h and an electricity cost of 32 $/MW h, the pay-off periods would be 3.3 and 2.9 years for compressor-driven and absorption heat pump alternatives, respectively. (C) 1997 by John Wiley & Sons, Ltd.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Nyckelord

energy conservation
paper drying
moist air
heat pumps

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abrahamsson, K
Stenström, Stig
Aly, Gharib
Jernqvist, Åke
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
Artiklar i publikationen
International Jo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy