SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:cfce0217-760f-425b-8224-1731469cf56d"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:cfce0217-760f-425b-8224-1731469cf56d" > Improved accuracy i...

Improved accuracy in time-resolved diffuse reflectance spectroscopy.

Alerstam, Erik (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Andersson-Engels, Stefan (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Svensson, Tomas (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2008
2008
Engelska.
Ingår i: Optics Express. - 1094-4087. ; 16:14, s. 10440-10454
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Significant improvements in the accuracy of time-resolved diffuse reflectance spectroscopy are reached by using a Monte Carlo scheme for evaluation of measured photon time-of-flight distributions. The use of time-resolved diffusion theory of photon migration, being the current standard scheme for data evaluation, is shown defective. In particular, the familiar problem sometimes referred to as absorption-to-scattering coupling or crosstalk, is identified as an error related to the breakdown of the diffusion approximation. These systematic errors are investigated numerically using Monte Carlo simulations, and their influence on data evaluation of experimental recordings are accurately predicted. The proposed Monte Carlo-based data evaluation avoids these errors, and can be used for routine data evaluation. The accuracy and reproducibility of both MC and diffusion modeling are investigated experimentally using the MEDPHOT set of solid tissue-simulating phantoms, and provides convincing arguments that Monte Carlo-based evaluation is crucial in important ranges of optical properties. In contrast to diffusion-based evaluation, the Monte Carlo scheme results in optical properties consistent with phantom design. Since the MEDPHOT phantoms are used for international comparisons and performance assessment, the performed characterization is carefully reported.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Alerstam, Erik
Andersson-Engels ...
Svensson, Tomas
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Atom och molekyl ...
Artiklar i publikationen
Optics Express
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy