Estimation of area at risk in myocardial infarction

Carnicky, J. (författare)
International Laser Center Bratislava
Ubachs, J. F.A. (författare)
Maastricht University Medical Centre
Mateasik, A. (författare)
International Laser Center Bratislava
visa fler...
Engblom, H. (författare)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
Arheden, H. (författare)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
Hedström, E. (författare)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
Wagner, G. S. (författare)
Duke University
Bacharova, L. (författare)
International Laser Center Bratislava
visa färre...
 (creator_code:org_t)
2007
2007
Engelska 4 s.
Ingår i: Computers in Cardiology 2007, CAR 2007. - 9781424425334 ; 34, s. 169-172
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study presents a new method for estimation and imaging of the area at risk (AaR) in myocardial infarction (MI). The values of the ST-segment deviations of 12-lead ECG signal were used as input parameters. Based on DECARTO model, the spherical surface was chosen as a reference surface to approximate the ventricular wall. On this surface, the spatial ST vector was projected. The center of AaR was defined as an intersection of the spatial ST vector with spherical surface; the size of the AaR was set to be proportional to the number of electrical leads with ST- segment deviations. The method was tested using data of 10 patients with acute MI. The visual comparison showed good agreement with the AaRECG estimates based originally on the Selvester QRS scoring as well as with a non- electrocardiographic imaging method (SPECT).

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy