Staphylococcus aureus bacteraemia, cardiac implantable electronic device, extraction, and the risk of recurrent infection; a retrospective population-based cohort study

Berge, Andreas (författare)
Karolinska Institutet,Karolinska Institute,Karolinska University Hospital
Carlsén, Casper (författare)
Karolinska Institute
Petropoulos, Alexandros (författare)
Karolinska Institutet,Karolinska Institute,Karolinska University Hospital
visa fler...
Gadler, Fredrik (författare)
Karolinska Institute,Karolinska University Hospital
Rasmussen, Magnus (författare)
Lund University,Lunds universitet,Infektionsmedicin,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Translationell infektionsmedicin,Forskargrupper vid Lunds universitet,Infection Medicine (BMC),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,Translational infection medicine,Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Infectious Diseases. - 2374-4235. ; 56:7, s. 543-553
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Patients with cardiac implantable electronic device (CIED) and Staphylococcus aureus bacteraemia (SAB) are at risk of having CIED infection, pocket infection or endocarditis. To avoid treatment failures, guidelines recommend that the CIED should be extracted in all cases of SAB butrecent studies indicate low extraction rates and low risk of relapse. The aim of the study was to describe a Swedish population-based cohort of patients with CIED and SAB, the rate of extraction, and treatment failure measured as recurrent SAB. Methods: Patients identified to have SAB in the Karolinska Laboratory database, serving a population of 1.9 million, from January 2015 through December 2019 were matched to the Swedish ICD and Pacemaker Registry. Patients with CIED and SAB were included. Clinical data were collected from medical records. Results: A cohort of 274 patients was identified and 38 patients (14%)had the CIED extracted. Factors associated with extraction were lower age, lower Charlson comorbidity index, shorter time since CIED implantation, and non-nosocomial acquisition, but not mortality. No patient was put on lifelong antibiotic treatment. Sixteen patients (6%) had a recurrent SAB within one year, two in patients subjected to extraction (5%) and 14 in patients not subjected to CIED-extraction (6%). Three of the 14 patients were found to have definite endocarditis during the recurrent episode. Conclusions: Despite a low extraction rate, there were few recurrences. We suggest that extraction of the CIED might be omitted if pocket infection, changes on the CIED, or definite endocarditis are not detected.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

and endocarditis
bacteraemia
CIED extraction
CIED infection
recurrent infection
relapse
Staphylococcus aureus

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy