Sökning: id:"swepub:oai:lup.lub.lu.se:d37b8d5d-fdcc-4d02-886e-2d42af360c73" >
The Reflector: a ne...
The Reflector: a new method for saving anaesthetic vapours
-
Perhag, L (författare)
-
- Reinstrup, Peter (författare)
- Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Thomasson, R (författare)
-
visa fler...
-
- Werner, Olof (författare)
- Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- 2000
- 2000
- Engelska.
-
Ingår i: British Journal of Anaesthesia. - 1471-6771. ; 85:3, s. 482-486
- Relaterad länk:
-
http://bja.oxfordjou... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- Anaesthesia systems that minimize the use of volatile anaesthetics to reduce cost and pollution are of interest. Closed circuit anaesthesia is the ideal solution, but requires continuous adjustment of fresh gas flow and composition and thus is demanding in routine practice. We describe an alternative system, the Reflector system, which is open in regard to oxygen, nitrogen and N2O, and semiclosed in regard to volatile anaesthetics. The Reflector system is a circle system with a carbon dioxide absorber and an automatic vapour delivery device placed in the inspiratory limb of the circle. A zeolite filter, the Reflector, is placed between the ventilator and the circle. The Reflector functions as a molecular sieve, preventing the volatile anaesthetic from leaving the circle. Isoflurane consumption using the Reflector system in bench tests and an animal study was compared with that of an open system. In bench tests consumption was reduced by 79% and 82%, at a respiratory frequency of 10 and 20 min-1, respectively. The corresponding mean figures from the animal experiment were 65% and 77%.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
Nyckelord
- anaesthetic techniques
- closed circuit
- inhalation
- anaesthetics volatile
- isoflurane
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas