SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:d48f9ac2-23ab-4537-953f-c46f44a2c95b"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:d48f9ac2-23ab-4537-953f-c46f44a2c95b" > Ultralow contrast m...

Ultralow contrast medium doses at CT to diagnose pulmonary embolism in patients with moderate to severe renal impairment: a feasibility study.

Kristiansson, Mattias (författare)
Geijer, Fredrik (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Nyman, Ulf (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
 (creator_code:org_t)
2009-12-24
2010
Engelska.
Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 20, s. 1321-1330
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVES: To analyse 80-kVp 16-MDCT in patients with clinically suspected pulmonary embolism (PE) and diminished renal function after a reduction in dose of contrast medium (CM) from 200 to 150 mg I/kg. METHODS: Fifty patients with suspected PE and glomerular filtration rate (GFR) less than 50 mL/min underwent 80-kVp 16-MDCT with 150 mg I/kg. Mean density/image noise (1 standard deviation) was measured in a region of interest in the left pulmonary artery (LPA) and a lower lobe segmental artery (LLSA), and the contrast-to-noise ratio (CNR) was calculated. The values of LPA and LLSA were averaged. RESULTS: Median values/2.5-97.5 percentiles were: age 84/67-96 years, weight 65/43-84 kg, GFR 36/21-45 mL/min, CM dose 9.6/6.4-12 g of iodine, PA density 353/164-495 HU and CNR 11/4.4-20. PE incidence was 16%, and 8% and 12% of the examinations were regarded suboptimal by observer 1 and 2, respectively. Density/CNR values were within ranges reported for common 120-kVp MDCT protocols. None of 32 patients with plasma-creatinine follow-up within 1 week experienced a rise of more than 44.2 mumol/L and none of 50 patients had oliguria/anuria or dialysis. None of 40 patients with a negative CT/no anticoagulation had thromboembolism during follow-up. CONCLUSION: 80-kVp MDCT combined with individualised ultralow CM doses may provide satisfactory diagnostic quality, which should be to the benefit of patients at risk of contrast medium-induced nephropathy.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Kristiansson, Ma ...
Geijer, Fredrik
Nyman, Ulf
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
European Radiolo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy