SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:d5e2f89a-a91d-4ba7-8941-a651e497b6e9"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:d5e2f89a-a91d-4ba7-8941-a651e497b6e9" > Model based robustn...

Model based robustness analysis of an ion-exchange chromatography step

Jakobsson, Niklas (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Degerman, Marcus (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
Stenborg, Emelie (författare)
visa fler...
Nilsson, Bernt (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673. ; 1138:1-2, s. 109-119
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Process development, optimization and robustness analysis for chromatographic separation are often entirely based on experimental work and generic knowledge. This paper describes a model-based approach that can be used to am process knowledge and assist in the robustness analysis of an ion-exchange chromatography step using a model-based approach. A kinetic dispersive model, where the steric mass action model accounts for the adsorption is used to describe column performance. Model calibration is based solely on gradient elution experiments at different gradients, flow rates, pH and column loads. The position and shape of the peaks provide enough information to calibrate the model and thus single-component experiments can be avoided. The model is calibrated to the experiments and the confidence intervals for the estimated parameters are used to account for the model error throughout the analysis. The model is used to predict the result of a robustness analysis conducted as a factorial experiment and to design a robust pooling approach. The confidence intervals are used in a "worst case" approach where the parameters for the components are set at the edge of their confidence intervals to create a worst case for the removal of impurities at each point in the factorial experiment. The pooling limit was changed to ensure product quality at every point in the factorial analysis. The predicted purities and yields were compared to the experimental results to ensure that the prediction intervals cover the experimental results. (c) 2006 Elsevier B.V. All rights reserved.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Nyckelord

preparative chromatography
chromatography
ion-exchange
simulation
modeling
robustness analysis
validation
process-scale chromatogaphy

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jakobsson, Nikla ...
Degerman, Marcus
Stenborg, Emelie
Nilsson, Bernt
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
Artiklar i publikationen
Journal of Chrom ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy