SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:d6542466-f691-4ac5-89d0-5cd70a80c1c1"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:d6542466-f691-4ac5-89d0-5cd70a80c1c1" > A general, extracor...

A general, extracorporeal immunoadsorption method to increase the tumor-to-normal tissue ratio in radioimmunoimaging and radioimmunotherapy

Norrgren, Kristina (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Strand, Sven-Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Nilsson, Rune (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Lindgren, L (författare)
Sjögren, H O (författare)
visa färre...
 (creator_code:org_t)
1993
1993
Engelska.
Ingår i: Journal of Nuclear Medicine. - 0161-5505. ; 34:3, s. 448-454
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to investigate a new extracorporeal immunoadsorption method to improve tumor-to-normal tissue ratios in radioimmunoimaging (RII) and radioimmunotherapy (RIT). We have developed and investigated a general method using biotinylated antibodies and an agarose-avidin column for extracorporeal immunoadsorption. The studies were made in an animal model and extracorporeal immunoadsorption (ECIA) was performed 24 or 48 hr after the injection of 125I-labeled biotinylated antibodies. In athymic rats, heterotransplanted with human malignant melanoma, 90%-95% of the circulating activity was removed with ECIA. The tumor-to-normal tissue ratios at 24 hr was increased 4 times (from 1.2 to 5.1) in the liver, 2.5 times (0.7 to 1.8) in the lung, 4 times (1 to 4) in the kidneys and 4 times (1.4 to 5) in the bone marrow. Whole body activity was reduced by 40%-50%. Tumor-to-organ ratios at 48 hr were increased 3.5 times (from 1.5 to 5.2) in the liver, 2 times (0.9 to 1.7) in the lung, 3 times (1.3 to 3.8) in the kidneys and 4 times (1.4 to 5.5) in the bone marrow. Whole body activity was reduced by 35% when ECIA was performed 48 hr after injection. This study proves that an important reduction in background activity, and thereby an improvement in the tumor-to-background ratio, can be achieved by using this generally applicable, biotin-avidin ECIA method. For RII, the improved ratio increases the possibilities of detecting tumors and metastases in blood-rich organs. For RIT, the procedure may lead to a decreased absorbed dose to bone marrow and other critical organs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy