SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:d8b98bc9-9271-4cec-9c31-1222b0cfe603"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:d8b98bc9-9271-4cec-9c31-1222b0cfe603" > Design guidelines f...

Design guidelines for fluid-elastic instability of tube bundles subjected to two-phase cross flow

Sun, Ning (författare)
Zhejiang University
Cheng, Rui jia (författare)
Zhejiang University
Zhang, Ya nan (författare)
Zhejiang University
visa fler...
Liu, Bao qing (författare)
Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,Zhejiang University
Sunden, Bengt (författare)
Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2019
2019
Engelska 13 s.
Ingår i: Journal of Zhejiang University: Science A. - 1673-565X. ; 20:8, s. 577-589
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Fluid-elastic instability of tube bundles is the main cause of vibration failure of heat exchangers. To establish more reasonable and reliable design guidelines for fluid-elastic instability of tube bundles subjected to two-phase cross flow, we investigated experimentally the effects of the flow conditions of the two-phase flow and the geometrical characteristics of the tube bundles on damping, vibration, and fluid-elastic instability. Moreover, we proposed recommended values of the instability constant based on the conductivity difference measurement (CDM) model and the classification of tube bundle arrangements. The reliability of these values was also verified. The results indicated that the damping ratio in the lift direction was smaller than that in the drag direction and fluid-elastic instability was more prone to occur. The order of stability of the four tube bundle arrangements from high to low was normal triangular, normal square, rotated square, and rotated triangular. Thus, to avoid fluid-elastic instability, the normal triangular tube bundle is recommended for large shell-and-tube heat exchangers subjected to two-phase cross flow. In addition, for normal square and normal triangular tube bundles, the recommended instability constant is 4.0. For rotated square and rotated triangular tube bundles, the recommended instability constant is 1.1 when the mass damping parameter is less than or equal to 0.54, otherwise the value is 1.5.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Nyckelord

Design guidelines
Fluid-elastic instability
TE965
TK172
Tube bundle
Two-phase cross flow

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sun, Ning
Cheng, Rui jia
Zhang, Ya nan
Liu, Bao qing
Sunden, Bengt
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Strömningsmekani ...
Artiklar i publikationen
Journal of Zheji ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy