SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:d97ba5ee-4588-44b1-91c8-8d3c5240cfcd"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:d97ba5ee-4588-44b1-91c8-8d3c5240cfcd" > Estimation of 3D ro...

Estimation of 3D rotation of femur in 2D hip radiographs

Vaananen, Sami P. (författare)
Isaksson, Hanna (författare)
Lund University,Lunds universitet,Hållfasthetslära,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Solid Mechanics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
Waarsing, Jan H. (författare)
visa fler...
Zadpoor, Amir Abbas (författare)
Jurvelin, Jukka S. (författare)
Weinans, Harrie (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2012
2012
Engelska.
Ingår i: Journal of Biomechanics. - : Elsevier BV. - 1873-2380 .- 0021-9290. ; 45:13, s. 2279-2283
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Femoral radiographs are affected by the degree of rotation of the femur with respect to the plane of projection. We aimed to determine the 3D rotation of the proximal femur in 2D radiographs. A 3D Statistical Appearance Model (SAM), which was built from CT images of cadaver proximal femurs (n = 33) was randomly sampled to form a training set of 500 bones. Nineteen clinical CT images were collected for testing. All CT images were rotated to +/- 20 degrees in 2 degrees division around the shaft axis, +/- 10 degrees around medial-lateral axis, and by simultaneous rotation of both axes (+/- 16 degrees and +/- 8 degrees around shaft and medial-lateral axes). In each orientation, a 2D projection was recorded for generating a 2D SAM. The outcome parameters of the 2D SAM were used as input for a linear regression model and an artificial neural network to predict the rotation. The artificial neural network estimated the rotation more accurately than the linear regression. For artificial neural networks the mean errors were 4.0 degrees and 2.0 degrees around the shaft and medial-lateral axes, respectively. For an individual radiograph, the confidence interval of estimation was still relatively large. However, this method has high potential to differentiate the amount of rotations in two image sets. (C) 2012 Elsevier Ltd. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

Rotation of femur
X-ray
Statistical appearance model
Artificial
neural networks

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy