Sökning: id:"swepub:oai:lup.lub.lu.se:d9ab34b5-486b-4610-bc07-69bc81b943b5" >
Ultrasound enhanced...
Ultrasound enhanced thrombolysis in experimental retinal vein occlusion in the rabbit
-
- Larsson, Jörgen (författare)
- Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Carlson, Jonas (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Olsson, Bertil (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
(creator_code:org_t)
- 1998
- 1998
- Engelska.
-
Ingår i: British Journal of Ophthalmology. - 1468-2079. ; 82:12, s. 1438-1440
- Relaterad länk:
-
http://bjo.bmj.com/c...
-
visa fler...
-
https://lup.lub.lu.s...
-
visa färre...
Abstract
Ämnesord
Stäng
- AIMS: To investigate if it was possible to lower the dose of streptokinase and maintain an effective thrombolysis by adding pulsed low energy ultrasound. METHODS: 53 retinal veins in 27 rabbits were occluded by rose bengal enhanced laser treatment. Six rabbits were treated with streptokinase (50,000 IU/kg), 10 rabbits were treated with a low dose of streptokinase (25,000 IU/kg), and 11 rabbits were treated with a low dose of streptokinase (25,000 IU/kg) and pulsed ultrasound during 1 hour. Fluorescein angiography was performed immediately before the thrombolytic treatment and after 12 hours. RESULTS: In the group treated with streptokinase (50,000 IU/kg) all vessels were open. In the group that was given streptokinase (25,000 IU/kg), 21% of the vessels were open. In the group that was treated with streptokinase (25,000 IU/kg) and ultrasound, 64% of the vessels were open. The difference between groups 2 and 3 is statistically significant (p = 0.011) CONCLUSION: Adding pulsed low energy ultrasound makes it possible to lower the dose of streptokinase while maintaining a good thrombolytic effect.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Oftalmologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Ophthalmology (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas