SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:d9ab34b5-486b-4610-bc07-69bc81b943b5"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:d9ab34b5-486b-4610-bc07-69bc81b943b5" > Ultrasound enhanced...

Ultrasound enhanced thrombolysis in experimental retinal vein occlusion in the rabbit

Larsson, Jörgen (författare)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Carlson, Jonas (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Olsson, Bertil (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
1998
1998
Engelska.
Ingår i: British Journal of Ophthalmology. - 1468-2079. ; 82:12, s. 1438-1440
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIMS: To investigate if it was possible to lower the dose of streptokinase and maintain an effective thrombolysis by adding pulsed low energy ultrasound. METHODS: 53 retinal veins in 27 rabbits were occluded by rose bengal enhanced laser treatment. Six rabbits were treated with streptokinase (50,000 IU/kg), 10 rabbits were treated with a low dose of streptokinase (25,000 IU/kg), and 11 rabbits were treated with a low dose of streptokinase (25,000 IU/kg) and pulsed ultrasound during 1 hour. Fluorescein angiography was performed immediately before the thrombolytic treatment and after 12 hours. RESULTS: In the group treated with streptokinase (50,000 IU/kg) all vessels were open. In the group that was given streptokinase (25,000 IU/kg), 21% of the vessels were open. In the group that was treated with streptokinase (25,000 IU/kg) and ultrasound, 64% of the vessels were open. The difference between groups 2 and 3 is statistically significant (p = 0.011) CONCLUSION: Adding pulsed low energy ultrasound makes it possible to lower the dose of streptokinase while maintaining a good thrombolytic effect.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Larsson, Jörgen
Carlson, Jonas
Olsson, Bertil
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
British Journal ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy