Sökning: id:"swepub:oai:lup.lub.lu.se:db492a95-1c41-4d85-a109-1c7f229a7cfc" >
Beamline 1511 at MA...
Beamline 1511 at MAX II, capabilities and performance
-
- Denecke, R. (författare)
- Uppsala University,Lund University
-
- Väterlein, P. (författare)
- Uppsala University,Lund University
-
- Bässler, M. (författare)
- Uppsala University,Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
visa fler...
-
- Wassdahl, N. (författare)
- Uppsala University
-
- Butorin, S. (författare)
- Uppsala University
-
- Nilsson, A. (författare)
- Uppsala University
-
- Rubensson, J. E. (författare)
- Uppsala University
-
- Nordgren, J. (författare)
- Uppsala University
-
- Mårtensson, N. (författare)
- Uppsala University,Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
- Nyholm, R. (författare)
- Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
-
visa färre...
-
(creator_code:org_t)
- 1999
- 1999
- Engelska 7 s.
-
Ingår i: Journal of Electron Spectroscopy and Related Phenomena. - 0368-2048. ; 101-103, s. 971-977
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The new undulator beamline 1511 at MAX-lab, now under commissioning, has been optimized for X-ray emission and photoelectron spectroscopies. Using an SX-700 high flux monochromator the accessible photon energy range is from 90 eV to about 1500 eV. The performance of the undulator agrees very well with the specifications, as shown by measurements using a photodiode. The energy resolution of the monochromator has been checked using absorption measurements in a gas cell. It was found to meet the expectations and exceeds a resolving power of 10 000 at 244 eV. The photon flux as a function of energy has been recorded as well and gives a maximum flux of 3×1013 photons/s/100 mA/0.1% BW. Beamlines 1511 and 1411 will be the first synchrotron beamlines making use of a so-called beam waist phenomenon, known from laser physics. We show results of ray-tracing calculations to determine the ultimate spot size on the sample location. The endstations to be used at this new beamline and their capabilities will be discussed as an example of the future use of this facility.
Ämnesord
- NATURVETENSKAP -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)
Nyckelord
- Beam waist
- Soft X-ray emission spectroscopy
- Soft X-ray monochromator
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Denecke, R.
-
Väterlein, P.
-
Bässler, M.
-
Wassdahl, N.
-
Butorin, S.
-
Nilsson, A.
-
visa fler...
-
Rubensson, J. E.
-
Nordgren, J.
-
Mårtensson, N.
-
Nyholm, R.
-
visa färre...
- Om ämnet
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Fysik
-
och Acceleratorfysik ...
- Artiklar i publikationen
-
Journal of Elect ...
- Av lärosätet
-
Lunds universitet