SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:db492a95-1c41-4d85-a109-1c7f229a7cfc"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:db492a95-1c41-4d85-a109-1c7f229a7cfc" > Beamline 1511 at MA...

Beamline 1511 at MAX II, capabilities and performance

Denecke, R. (författare)
Uppsala University,Lund University
Väterlein, P. (författare)
Uppsala University,Lund University
Bässler, M. (författare)
Uppsala University,Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
visa fler...
Wassdahl, N. (författare)
Uppsala University
Butorin, S. (författare)
Uppsala University
Nilsson, A. (författare)
Uppsala University
Rubensson, J. E. (författare)
Uppsala University
Nordgren, J. (författare)
Uppsala University
Mårtensson, N. (författare)
Uppsala University,Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Nyholm, R. (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
visa färre...
 (creator_code:org_t)
1999
1999
Engelska 7 s.
Ingår i: Journal of Electron Spectroscopy and Related Phenomena. - 0368-2048. ; 101-103, s. 971-977
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The new undulator beamline 1511 at MAX-lab, now under commissioning, has been optimized for X-ray emission and photoelectron spectroscopies. Using an SX-700 high flux monochromator the accessible photon energy range is from 90 eV to about 1500 eV. The performance of the undulator agrees very well with the specifications, as shown by measurements using a photodiode. The energy resolution of the monochromator has been checked using absorption measurements in a gas cell. It was found to meet the expectations and exceeds a resolving power of 10 000 at 244 eV. The photon flux as a function of energy has been recorded as well and gives a maximum flux of 3×1013 photons/s/100 mA/0.1% BW. Beamlines 1511 and 1411 will be the first synchrotron beamlines making use of a so-called beam waist phenomenon, known from laser physics. We show results of ray-tracing calculations to determine the ultimate spot size on the sample location. The endstations to be used at this new beamline and their capabilities will be discussed as an example of the future use of this facility.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Nyckelord

Beam waist
Soft X-ray emission spectroscopy
Soft X-ray monochromator

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy