SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:db985214-ff67-41ba-8c54-7bd517ca6bd8"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:db985214-ff67-41ba-8c54-7bd517ca6bd8" > Multi-beam X-ray pt...

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Lyubomirskiy, Mikhail (författare)
German Electron Synchrotron (DESY)
Wittwer, Felix (författare)
Lawrence Berkeley National Laboratory,German Electron Synchrotron (DESY),University of Hamburg
Kahnt, Maik (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
visa fler...
Koch, Frieder (författare)
GSI Helmholtz Centre for Heavy Ion Research,Paul Scherrer Institute
Kubec, Adam (författare)
XRnanotech GmbH,Paul Scherrer Institute
Falch, Ken Vidar (författare)
German Electron Synchrotron (DESY)
Garrevoet, Jan (författare)
German Electron Synchrotron (DESY)
Seyrich, Martin (författare)
German Electron Synchrotron (DESY),University of Hamburg
David, Christian (författare)
Paul Scherrer Institute
Schroer, Christian G. (författare)
University of Hamburg,German Electron Synchrotron (DESY)
visa färre...
 (creator_code:org_t)
2022-04-13
2022
Engelska.
Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 12:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy