SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:dbbda7f8-95c2-4c60-8b0f-ed1364706b3a"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:dbbda7f8-95c2-4c60-8b0f-ed1364706b3a" > Patch testing with ...

Patch testing with methyldibromo glutaronitrile, a multicentre study within the EECDRG

Gruvberger, Birgitta (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
Andersen, KE (författare)
Brandao, FM (författare)
visa fler...
Bruynzeel, DP (författare)
Bruze, Magnus (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
Frosch, PJ (författare)
Goossens, A (författare)
Lahti, A (författare)
Lindberg, M (författare)
Karolinska Institutet
Menne, T (författare)
Orton, D (författare)
Seidenari, S (författare)
visa färre...
 (creator_code:org_t)
Wiley, 2005
2005
Engelska.
Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 52:1, s. 14-18
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Contact allergy to and allergic contact dermatitis from methyldibromo glutaronitrile (MDBGN) have frequently been reported. As there has been no agreement on which MDBGN test preparation to use, a study was initiated to help determine the optimal patch test preparation for MDBGN. 2661 consecutively patch tested patients at 11 test clinics representing 9 European countries participated. Petrolatum preparations with MDBGN at 1.0%, 0.5%, 0.3% and 0.1% were inserted in the standard series. Contact allergy rates were noted in the range 4.4-1.1% following decreasing test concentrations. Reactions not fulfilling all criteria to be classified as allergic reactions could represent either weak allergic or irritant reactions, and such reactions were noted in the range 8.2-0.5% with decreasing concentrations. A significant number of these reactions represented weak allergic reactions, as allergic reactions were obtained to higher patch test concentrations in the same individual. Morphologically irritant reactions were noted only for the highest test concentrations. In summary, the contact allergy rates and frequencies of doubtful and irritant reactions vary with the patch test concentration. The final decision on patch test concentration for MDBGN should not only rely on these factors but also include information on patch test concentrations required to diagnose individual cases with allergic contact dermatitis from MDBGN as well as results of repeated open application tests.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Dermatologi och venereologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dermatology and Venereal Diseases (hsv//eng)

Nyckelord

Tektamer 38
preservative
methyldibromo glutaronitrile
Euxyl K400
series
European standard test
contact allergy
CAS 35691-65-7
dermatitis
allergic contact
4-dicyanobutane
2-dibromo-2
1
adverse reactions

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy