A Method for Arterial Diameter Change Measurements Using Ultrasonic B-Mode Data.

Cinthio, Magnus (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Jansson, Tomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Medicinsk teknik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Biomedical Engineering, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Rydén Ahlgren, Åsa (författare)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
visa fler...
Lindström, Kjell (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Persson, Hans W (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2010
2010
Engelska.
Ingår i: Ultrasound in Medicine and Biology. - : Elsevier BV. - 0301-5629. ; 36:9, s. 1504-1512
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Arterial diameter change is related to distending blood pressure and is used in estimation of arterial stiffness parameters. A common technique to track the arterial walls is by integration of wall velocities estimated by different methods using cross correlation or tissue Doppler. However, because of the high pulse repetition frequency and the need for separate pulsing sequences, the B-mode image quality is affected. We have previously developed a fast algorithm for direct measurement of lumen diameter using B-mode images. In this study we have improved the technique to be more robust and also implemented measurements of diameter change, maximum differential wall velocity and relative diameter change of the common carotid artery noninvasively in vivo. The influence of the lateral width of the region of interest (ROI; 1 pixel, 0.1 mm, 0.5 mm, 1 mm, 2.5 mm and 5 mm) was evaluated. Using the optimal lateral width (2.5 mm), the systematic and random differences between two consecutive measurements were 21 mum and 105 mum, respectively, for lumen diameter measurement; -7 mum and 39 mum, respectively, for lumen diameter change measurements; -0.2 mm/s and 0.9 mm/s, respectively, for maximum relative wall velocity; and -0.2 % and 0.8 %, respectively, for measurements of the relative diameter change. The coefficient of variation (CV) was 1.9%, 5.2%, 7.9% and 6.0%, respectively. The study indicates that the reproducibility is sufficient for in vivo studies when the width of the ROI is 1.0 mm or wider. (E-mail: magnus.cinthio@elmat.lth.se).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy