SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:dfd6250d-8b64-4de4-affe-7ba9d90b76a9"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:dfd6250d-8b64-4de4-affe-7ba9d90b76a9" > Low-flow anaesthesi...

Low-flow anaesthesia with desflurane: kinetics during clinical procedures

Johansson, Anders (författare)
Lund University,Lunds universitet,Hälsa i ett tvärvetenskapligt perspektiv,Forskargrupper vid Lunds universitet,Integrative Health Research,Lund University Research Groups
Lundberg, Dag (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Luttropp, Hans-Henrik (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
2001
2001
Engelska.
Ingår i: European Journal of Anaesthesiology. - 1365-2346. ; 18:8, s. 499-504
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND AND OBJECTIVE: Low-flow anaesthesia is economical and less polluting. The purpose of this study was to determine the inspired and end-tidal desflurane concentrations during anaesthesia with a vaporizer setting maintained at 5%, during low-flow anaesthesia after 120 min with fresh gas inflows of 1.0 and 2.0 L min-1. METHODS: The study was both prospective and randomized, including 56 patients (28 patients in each group) scheduled for elective surgery of an expected anaesthesia time of at least 120 min. Inspired and end-tidal concentrations of desflurane were measured during low-flow anaesthesia with fresh gas inflows of 1.0 and 2.0 L min-1. The vaporizer setting was fixed at 5% desflurane. RESULTS: The inspired and end-tidal concentrations of desflurane in the 1.0 L min-1 group after 120 min were 4.54% vs. 4.37% (P < 0.001). In the 2.0 L min-1 group, the inspired and end-tidal concentrations of desflurane were 4.76% vs. 4.58% (P < 0.001). The estimated end-tidal/inspired ratios at 120 min of anaesthesia were 0.96 in both groups. At a fresh gas flow of 1.0 L min-1, the end-tidal concentration was 0.87 of the vaporizer setting. Increasing the fresh gas flow to 2.0 L min-1 increased the end-tidal value by 0.05. CONCLUSION: There is a significant difference between the inspired and end-tidal concentrations of desflurane when fresh gas inflows were 1.0 and 2.0 L min-1, but not for the ratio of inspired/end-tidal.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Johansson, Ander ...
Lundberg, Dag
Luttropp, Hans-H ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Anestesi och int ...
Artiklar i publikationen
European Journal ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy