SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:e8ec5c1e-2479-4d6b-9198-2e283049be18"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:e8ec5c1e-2479-4d6b-9198-2e283049be18" > Neurite guidance on...

Neurite guidance on protein micropatterns generated by a piezoelectric microdispenser

Gustavsson, Per (författare)
Lund University,Lunds universitet,Biologiska institutionen,Naturvetenskapliga fakulteten,Department of Biology,Faculty of Science
Johansson, Fredrik I (författare)
Lund University,Lunds universitet,Biologiska institutionen,Naturvetenskapliga fakulteten,Department of Biology,Faculty of Science
Kanje, Martin (författare)
Lund University,Lunds universitet,Biologiska institutionen,Naturvetenskapliga fakulteten,Department of Biology,Faculty of Science
visa fler...
Wallman, Lars (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Neurala gränsytor,Forskargrupper vid Lunds universitet,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Neural Interfaces,Lund University Research Groups
Eriksson Linsmeier, Cecilia (författare)
Lund University,Lunds universitet,Biologiska institutionen,Naturvetenskapliga fakulteten,Department of Biology,Faculty of Science
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: Biomaterials. - : Elsevier BV. - 1878-5905 .- 0142-9612. ; 28:6, s. 1141-1151
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study, we developed a microdispenser technique in order to create protein patterns for guidance of neurites from cultured adult mouse dorsal root ganglia (DRG). The microdispenser is a micromachined silicon device that ejects 100 picolitre droplets and has the ability to position the droplets with a precision of 6-8 mu m. Laminin and bovine serum albumin (BSA) was used to create adhesive and non-adhesive protein lines on polystyrene surfaces (cell culture dishes). Whole-mounted DRGs were then positioned close to the patterns and neurite outgrowth was monitored. The neurites preferred to grow on laminin lines as compared to the unpatterned plastic. When patterns were made from BSA the neurites preferred to grow in between the lines on the unpatterned plastic surface. We conclude that microdispensing can be used for guidance of sensory neurites. The advantages of microdispensing is that it is fast, flexible, allows deposition of different protein concentrations and enables patterning on delicate surfaces due to its non-contact mode of operation. It is conceivable that microdispensing can be utilized for the creation of protein patterns for guiding neurites to obtain in vitro neural networks, in tissue engineering or rapid screening for guiding proteins. (c) 2006 Elsevier Ltd. All rights reserved.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik -- Bioteknisk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology -- Bioengineering Equipment (hsv//eng)

Nyckelord

protein
nerve regeneration
micropatterning
nerve tissue engineering
cell adhesion

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy