Aptamer microarray mediated capture and mass spectrometry identification of biomarker in serum samples.
-
Ji-Young, Ahn (författare)
-
- Lee, Sang Wook (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Kang, Hye Suk (författare)
-
visa fler...
-
Jo, Minjoung (författare)
-
Lee, Dong-Ki (författare)
-
- Laurell, Thomas (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Kim, Soyoun (författare)
-
visa färre...
-
(creator_code:org_t)
- 2010-09-24
- 2010
- Engelska.
-
Ingår i: Journal of Proteome Research. - : American Chemical Society (ACS). - 1535-3893 .- 1535-3907. ; 9:11, s. 5568-5573
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Sensitive detection of molecular biomarkers in clinical samples is crucially important in disease diagnostics. This paper reports the developement of an aptamer microarray platform combined with sol-gel technology to identify low-abundance targets in complex serum samples. Because of the nanoporous structure of the sol-gel, a high capacity to immobilize the affinity specific aptamers is accomplished which allows binding and detection of target molecules with high sensitivity. The captured protein is digested in situ and the obtained digest was analyzed by ESI-MS without any interference from the affinity probe. TBP (TATA Box Protein) and its specific aptamers were chosen as a model system. A proof of concept with protein concentrations ranging between nanomolar to micromolar is reported, showing a good linearity up to 400 nM when characterized in an aptamer sandwich assay. Moreover, as low as 0.001% of target protein present in total serum proteins could be identified without any pretreatment step using ESI MS/MS mass spectrometry. We believe this novel strategy could become an efficient method for aptamer-based biomarker detection linked directly to mass spectrometry readout.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering (hsv//eng)
Nyckelord
- sol-gel immobilization
- aptamer microarray
- sandwich assay
- biomarkers
- ESI MS/MS mass spectrometry