SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:eeccb925-afd0-4cb7-ac8f-41f3d98cc2ae"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:eeccb925-afd0-4cb7-ac8f-41f3d98cc2ae" > Design and Control ...

Design and Control of an Electronic Bouncer Circuit for Volume-Optimal Long-Pulse High-Power Pulse Transformers

Collins, Max (författare)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,LTH profilområde: Energiomställningen,LTH profilområden,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: The Energy Transition,LTH Profile areas,Faculty of Engineering, LTH,European Spallation Source ESS AB
Martins, Carlos A. (författare)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,European Spallation Source ESS AB
 (creator_code:org_t)
2022
2022
Engelska 9 s.
Ingår i: IEEE Transactions on Plasma Science. - 0093-3813. ; 50:10, s. 3692-3700
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Pulse transformer size is fundamentally linked to application pulselength, pulse power and pulse rise time. In considering long-pulse high-power applications, it has earlier been demonstrated that the large voltage-time integral associated with long-pulse operation in combination with the severe pulse rise time required to ensure high pulse efficiency strictly limits the number of transformer winding turns thereby resulting in extremely large pulse transformers. This article investigates a new way of sizing and controlling an electronic bouncer circuit in reducing the effective pulse rise time. It is demonstrated that, in considering typical long-pulse application parameters, the pulse rise time may generally be reduced by a factor of 2, implying that pulse efficiency could be retained while significantly reducing pulse transformer volume. The developed idea is used in formulating a unified design procedure for volume-optimal pulse transformers with an electronic bouncer circuit. The method and proposed design procedure are illustrated and evaluated in a case study considering the European Spallation Source klystron modulator requirements (pulse amplitude of 115 kV/100 A, pulselength of 3.5 ms, pulse repetition rate of 14 Hz, and pulse rise time of < 120~μs). Finally, the proposed design procedure is used to evaluate the greatest attainable pulselength for a given set of application parameters and as a function of system constraints.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Accelerator power supplies
high voltage techniques
pulse generation
pulse power systems

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Collins, Max
Martins, Carlos ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
Artiklar i publikationen
IEEE Transaction ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy