Sökning: id:"swepub:oai:lup.lub.lu.se:ef9cd724-9576-400c-9427-a56fae123bba" >
Multiplex detection...
Multiplex detection of human herpesviruses from archival specimens by using matrix-assisted laser desorption ionization-time of flight mass spectrometry.
-
- Sjöholm, Malin (författare)
- Lund University,Lunds universitet,Klinisk mikrobiologi, Malmö,Forskargrupper vid Lunds universitet,Clinical Microbiology, Malmö,Lund University Research Groups
-
- Dillner, Joakim (författare)
- Karolinska Institutet,Lund University,Lunds universitet,Klinisk mikrobiologi, Malmö,Forskargrupper vid Lunds universitet,Clinical Microbiology, Malmö,Lund University Research Groups
-
- Carlson, Joyce (författare)
- Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
-
(creator_code:org_t)
- 2008
- 2008
- Engelska.
-
Ingår i: Journal of Clinical Microbiology. - 1098-660X. ; 46:2, s. 540-545
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- The human herpesviruses are involved in a variety of diseases. Large-scale evaluation of the clinical and epidemiological importance of different herpesviruses requires high-throughput methods. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a method that has a multiplex capacity enabling simultaneous detection of several viruses in a single sample. PCR-based methods for the multiplex detection of all known human herpesviruses were developed on the MALDI-TOF MS system. A variety of 882 archival samples, including bronchoalveolar lavage, conjunctival fluid, sore secretion, blister material, plasma, serum, and urine, analyzed for herpesviruses using PCR-based reference methods, were used to evaluate the MALDI-TOF MS method. The overall concordance rate between the MALDI-TOF MS method and the reference methods was 95.6% (kappa = 0.90). In summary, the MALDI-TOF MS method is well suited for large-scale detection of all known human herpesviruses in a wide variety of archival biological specimens.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Mikrobiologi inom det medicinska området (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Microbiology in the medical area (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas