SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:f035af82-4f99-41ce-bc1d-e90c78a66fba"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:f035af82-4f99-41ce-bc1d-e90c78a66fba" > Proposals for the e...

Proposals for the establishment of national diagnostic reference levels for radiography for adult patients based on regional dose surveys in Russian Federation

Vodovatov, A. V. (författare)
Research Institute of Radiation Hygiene named after Professor P.V. Ramzaev
Balonov, Mikhail I. (författare)
Research Institute of Radiation Hygiene named after Professor P.V. Ramzaev
Golikov, V. Yu (författare)
Research Institute of Radiation Hygiene named after Professor P.V. Ramzaev
visa fler...
Shatsky, I. G. (författare)
Research Institute of Radiation Hygiene named after Professor P.V. Ramzaev
Chipiga, L. A. (författare)
Research Institute of Radiation Hygiene named after Professor P.V. Ramzaev
Bernhardsson, C. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
visa färre...
Research Institute of Radiation Hygiene named after Professor PV. Ramzaev Medicinsk strålningsfysik, Malmö (creator_code:org_t)
2016-11-24
2017
Engelska 10 s.
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 173:1, s. 223-232
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In 2009-2014, dose surveys aimed to collect adult patient data and parameters of most common radiographic examinations were performed in six Russian regions. Typical patient doses were estimated for the selected examinations both in entrance surface dose and in effective dose. 75%-percentiles of typical patient effective dose distributions were proposed as preliminary regional diagnostic reference levels (DRLs) for radiography. Differences between the 75%-percentiles of regional typical patient dose distributions did not exceed 30-50% for the examinations with standardized clinical protocols (skull, chest and thoracic spine) and a factor of 1.5 for other examinations. Two different approaches for establishing national DRLs were evaluated: as a 75%-percentile of a pooled regional sample of patient typical doses (pooled method) and as a median of 75%- percentiles of regional typical patient dose distributions (median method). Differences between pooled and median methods for effective dose did not exceed 20%. It was proposed to establish Russian national DRLs in effective dose using a pooled method. In addition, the local authorities were granted an opportunity to establish regional DRLs if the local radiological practice and typical patient dose distributions are significantly different.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy