SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:f19d8f8c-a2da-45fb-a0e3-0efd16532442"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:f19d8f8c-a2da-45fb-a0e3-0efd16532442" > Impedance Matching ...

Impedance Matching for VSC-HVDC Damping Controller Gain Selection

Safari, Reza (författare)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Samuelsson, Olof (författare)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Svensson, Jörgen (författare)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Pates, Richard (författare)
Lund University,Lunds universitet,Institutionen för reglerteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Automatic Control,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2018
2018
Engelska.
Ingår i: IEEE Transactions on Power Systems. - 0885-8950.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The impedance matching concept is employed in this paper to select the optimum gain of a VSC-HVDC damping controller. The damping controller of the DC link is based on control of active power in proportion to the difference in local frequency at the VSC-HVDC converter stations. To explain impedance matching, the small-disturbance electro-mechanical dynamics of a power system is transformed to an equivalent LC-circuit. The VSC-HVDC damping controller corresponds to introducing a resistor in the circuit model. Using impedance matching to select resistor value in the circuit model is equivalent to selecting damping controller gain that gives maximum damping ratio. An analytical derivation is conducted for a linearized model of a generic two-area power system, including an expression for the optimum gain. It is also shown how the concept may be employed without a circuit model and that the optimum value is hardly affected by changes in power flow. Then the performance of the proposed approach in multi-mode test systems and with nonlinearities is evaluated using dynamic simulations in DIgSILENT PowerFactory. The results show that impedance matching maximizes the targeted mode damping ratio while non-targeted modes are not negatively impacted.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Safari, Reza
Samuelsson, Olof
Svensson, Jörgen
Pates, Richard
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
och Reglerteknik
Artiklar i publikationen
IEEE Transaction ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy