SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:f5709206-0ca7-4ccd-911c-5295522fa29d"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:f5709206-0ca7-4ccd-911c-5295522fa29d" > Automatic Screening...

Automatic Screening of Atrial Fibrillation in Thumb-ECG Recordings

Stridh, Martin (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
Rosenqvist, Marten (författare)
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: 2012 Computing in Cardiology (Cinc), Vol 39. - 0276-6574. ; , s. 193-196
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The present study proposes a novel sorting algorithm for identification of patients with atrial fibrillation in large one-lead ECG repositories. Repeated measurements at home with automatic transmission of data to a central database is presently tested in the search for atrial fibrillation for the long-term purpose to reduce the incidence of stroke. Such screening rapidly generates large databases of signals waiting to be sorted and prioritized. The one-lead ECGs were first preprocessed to remove baseline wander followed by beat detection and beat classification. A rhythm analysis stage was employed to perform RR interval analysis with negligible influence of ectopic beats and disturbances. RR interval information in combination with a waveform clustering procedure applied to the expected P wave intervals were used to sort the database into a low priority group containing mainly sinus rhythm, a high priority group containing all ECGs with irregular beat patterns, and a third group showing an unreliable RR series. The outcome of the algorithm was compared to an annotated database containing 2837 one-lead ECG recordings from 103 patients where each recording was visually inspected by a physician. The proposed method was able to divide the database into a low-priority group containing 93% (n=2357) of the sinus rhythm cases and a high priority group containing 98% (n=55) of the atrial fibrillation cases. In addition, 3.7% were found to have an unreliable RR series. In conclusion, automatic analysis of one-lead ECG databases can quickly guide the physician to find recordings with high probability to contain atrial fibrillation and can automatically indicate if a recording needs to be remade due to quality problems.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Stridh, Martin
Rosenqvist, Mart ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
Artiklar i publikationen
2012 Computing i ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy