SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:f7e197e1-6424-4a43-948c-db6d84ce734f"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:f7e197e1-6424-4a43-948c-db6d84ce734f" > CT and MR imaging o...

CT and MR imaging of the liver using liver-specific contrast media. A comparative study in a tumour model

Leander, Peter (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Månsson, S (författare)
Ege, T (författare)
visa fler...
Besjakov, Jack (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
1996
1996
Engelska.
Ingår i: Acta Radiologica. - 1600-0455. ; 37:3 Pt 1, s. 242-249
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: A new type of liposomal liver-specific contrast medium (CM) in CT was studied, and the results were compared with those obtained with Mn-DPDP, a paramagnetic hepatobiliary CM, in MR imaging. The contrasts of normal liver tissue to tumorous tissue and the importance of the CM for tumour detection in the 2 modalities were studied in a rabbit tumour model. CT and T1-weighted pre- and postcontrast and T2-weighted MR images precontrast were obtained. MATERIAL, METHODS AND RESULTS: Compared to precontrast images, significantly higher contrasts of normal liver tissue to tumorous tissue were obtained after CM administration in both CT and MR examinations. At radiologic evaluation, significantly more tumours were detected after CM administration in CT and in T1-weighted MR images than in precontrast images in CT and T1-weighted MR. There were no significant differences in tumour detection frequency in MR studies including a T2-weighted pulse sequence, postcontrast CT, or postcontrast T1-weighted MR imaging. CONCLUSION: The use of liver-specific CM improves visualization of liver tumours in CT and T1-weighted MR imaging.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Leander, Peter
Månsson, S
Ege, T
Besjakov, Jack
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Acta Radiologica
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy