Performance of two relatively new quantitative D-dimer assays (Innovance D-dimer and AxSYM D-dimer) for the exclusion of deep vein thrombosis.

Elf, Johan (författare)
Lund University,Lunds universitet,Klinisk koagulationsmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Coagulation, Malmö,Lund University Research Groups
Strandberg, Karin (författare)
Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
Svensson, Peter (författare)
Lund University,Lunds universitet,Klinisk koagulationsmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Coagulation, Malmö,Lund University Research Groups
 (creator_code:org_t)
Elsevier BV, 2009
2009
Engelska.
Ingår i: Thrombosis Research. - : Elsevier BV. - 1879-2472 .- 0049-3848. ; 124, s. 701-705
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • INTRODUCTION: D-dimer assays are now widely used as the first-line test in the diagnostic algorithm of suspected deep vein thrombosis (DVT). The aim of this study was to evaluate the performance of two relatively new quantitative D-Dimer assays (Innovance and AxSYM(R)) by comparison with a clinical gold standard. PATIENTS AND METHODS: 311 samples from outpatients with clinical suspicion of DVT, included in a prospective management study, was analysed (prevalence of DVT 23%). The diagnostic workup included estimation of pre-test probability, D-dimer determination, objective imaging as well as 3 month clinical follow up of negative patients. RESULTS: No significant differences were seen in sensitivity and negative predictive values between Innovance, AxSYM and the reference assays. The area under the ROC curve was slightly lower for the AxSYM assay and the correlation to the reference assays was only moderate (r<0.8) whereas the agreement with the Vidas assay was near excellent (kappa=0.8). The Innovance assay reached the highest AUC, showed a strong correlation with the reference assays (r>/=0.9) and a good agreement with the Vidas assay (kappa=0.76). In combination with a low pre-test probability score the Innovance assay reached a NPV of 100% (95% CI, 92-100) and the AxSYM assay 98% (95% CI, 87-100). CONCLUSION: The Innovance and AxSYM assays show an overall good and comparable performance for the exclusion of DVT when compared to the established assays. Our results for the AxSYM assay indicate that the optimal cut-off value needs to be further evaluated.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Elf, Johan
Strandberg, Kari ...
Svensson, Peter
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Thrombosis Resea ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy