Statistical methods for monitoring the relationship between the IFCC reference measurement procedure for hemoglobin A(1c) and the designated comparison methods in the United States, Japan, and Sweden

Geistanger, Andrea (författare)
Arends, Sabine (författare)
Berding, Christoph (författare)
visa fler...
Hoshino, Tadao (författare)
Jeppsson, Jan-Olof (författare)
Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
Little, Randie (författare)
Siebelder, Carla (författare)
Weykamp, Cas (författare)
visa färre...
 (creator_code:org_t)
2008-08-01
2008
Engelska.
Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 54:8, s. 1379-1385
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: The American Diabetes Association (ADA)/European Association for the Study of Diabetes (EASD)/International Diabetes Federation GDFAFCC Consensus Statement on the worldwide standardization of HbA(1c) states that"...[HbA(1c)] results are to be reported world-wide in IFCC units...and derived NGSP units...,using the IFCC-NGSP master equation." METHODS: We describe statistical methods to evaluate and monitor the relationships as expressed in master equations (MEs) between the IFCC Reference Measurement procedure (IFCC-RM) and designated comparison methods (DCMs) [US National Glycohemoglobin Standardization Program (NGSP), Japanese Diabetes Society/Japanese Society for Clinical Chemistry (JDS/JSCC), and Mono-S in Sweden]. We applied these statistics, including uncertainty calculations, to 12 studies in which networks of reference laboratories participated, operating the IFCC-RM and DCMs. RESULTS: For NGSP and Mono-S, slope, intercept, and derived percentage HbA(1c) at the therapeutic target show compliance with the respective MEs in all 12 studies. For JDS/JSCC, a slight deviation is seen in slope and derived percentage HbA(1c) in 2 of the 12 studies. Using the MEs, the uncertainty in an assigned value increases from 0.42 mmol/mol HbA(1c) (IFCC-RM) to 0.47 (NGSP), 0.49 (JDS/JSCC), and 0.51 (Mono-S). CONCLUSIONS: We describe sound statistical methods for the investigation of relations between networks of reference laboratories. Application of these statistical methods to the relationship between the JFCC-RM and DCMs in the US, Japan, and Sweden shows that they are suitable for the purpose, and the results support the applicability of the ADA/EASD/lDF/lFCC Consensus Statement on HbA1c measurement. (C) 2008 American Association for Clinical Chemistry.

Ämnesord

NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy