Sökning: id:"swepub:oai:lup.lub.lu.se:ff64ea42-1455-463a-b2bf-e1c98bbeb699" >
Intracapsular press...
Intracapsular pressure and loosening of hip prostheses. Preoperative measurements in 18 hips
-
- Robertsson, Otto (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Wingstrand, Hans (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Kesteris, Uldis (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa fler...
-
- Jonsson, Kjell (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Önnerfält, Rolf (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- 2009-07-08
- 1997
- Engelska.
-
Ingår i: Acta Orthopaedica Scandinavica. - : Medical Journals Sweden AB. - 0001-6470. ; 68:3, s. 231-234
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.3...
-
visa färre...
Abstract
Ämnesord
Stäng
- We measured the intracapsular pressure preoperatively in 18 hips (17 patients) before revision of a total hip arthroplasty because of aseptic loosening. Distension of the joint capsule was measured with sonography in 13 cases. In extension, the mean intracapsular pressure was 26 (0-60) mmHg, in extension and inward rotation it was 159 (24-280) mmHg, in extension and outward rotation it was 30 (3-67) mmHg and in 45 degrees of flexion it was 12 (0-28) mmHg. A mean of 6 (0.5-20) mL of joint fluid was aspirated after the pressure measurements. Sonography showed increased joint fluid/synovial edema and/or increased capsular thickness, as compared to 34 unrevised, radiographically not loose prosthetic hips, and that the capsular distension correlated to intracapsular pressure during extension and inward rotation. We conclude that the intracapsular pressure usually is elevated in a hip joint with loose prosthetic components, that the intracapsular pressure varies with the position of the hip and that capsular distension reflects increased intracapsular pressure. The increased and often very high pressure, varying during gait, may pump debris away from the joint along the interfaces and even by itself cause osteolysis and loosening.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas