SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:ffe8b33a-110e-4bc5-8f43-2386712437b0"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:ffe8b33a-110e-4bc5-8f43-2386712437b0" > Automatic fermentat...

Automatic fermentation control based on a real-time in situ SIRE (R) biosensor regulated glucose feed

Lidgren, L (författare)
Lija, O (författare)
Krook, M (författare)
visa fler...
Kriz, Dario (författare)
Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2006
2006
Engelska.
Ingår i: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 21:10, s. 2010-2013
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Monitoring and regulation of fermentations is of a paramount industrial and academic importance in order to keep conditions optimal during the entire process. Established techniques employed today include HPLC and spectrophotometry, which both have the disadvantage that broth samples have to be drawn from the fermentor and that they often require sample pre-treatment. The objectives of this study was to design and evaluate a software controlled automatic real-time SIRE (R) biosensor connected to a glucose feed solution pump for in situ based monitoring and regulation of the glucose concentration during a yeast fermentation process. The maximal frequency for the measuring-regulation cycles was 30/h. A 10 mM mean glucose concentration level was successfully maintained within +/- 0.013 mM during 60 min fermentations at various concentrations of yeast (10, 20, 40 and 80 g/l). The on/off-regulator used caused some expected fluctuations (oscillations) of the glucose concentration around the mean value (0.12 mM at 10 g/l, +/- 0.26 mM at 20 g/l, +/- 0.51 mM at 40 g/l, and +/- 0.99 mM at 80 g/l). A 7-h fermentation process (10 mM glucose and 20 g/l yeast) was successfully monitored and regulated. The obtained measuring data were found to be 8.5-22.9% lower than data obtained with a commercially available spectrophotometric kit. The difference increased linearly (-0.26 mM/h), during the fermentation process and indicated that some clogging of the in situ positioned probe occurred. The speed and the automatisation adaptability of the presented device suggest advantages compared to established techniques.

Ämnesord

NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Nyckelord

in situ
regulation
real-time fermentation control

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lidgren, L
Lija, O
Krook, M
Kriz, Dario
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Biologi
och Biokemi och mole ...
Artiklar i publikationen
Biosensors & Bio ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy