SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:prod.swepub.kib.ki.se:130301962"
 

Sökning: id:"swepub:oai:prod.swepub.kib.ki.se:130301962" > Contrast-enhanced u...

Contrast-enhanced ultrasound using real-time contrast harmonic imaging in invasive breast cancer: comparison of enhancement dynamics with three different doses of contrast agent

Saracco, A (författare)
Karolinska Institutet
Szabo, BK (författare)
Aspelin, P (författare)
Karolinska Institutet
visa fler...
Leifland, K (författare)
Tanczos, E (författare)
Wilczek, B (författare)
Axelsson, R (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2015-01-01
2015
Engelska.
Ingår i: Acta radiologica (Stockholm, Sweden : 1987). - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 56:1, s. 34-41
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In the last few years new potential applications have been developed for contrast-enhanced ultrasound (CEUS) and the management of breast diseases, but there is still some debate concerning the optimal dose to evaluate breast lesions, especially as a diagnostic tool. Purpose To compare different CEUS doses of injected contrast agent in order to establish an optimal dose for the diagnosis of invasive breast cancer. Material and Methods In Group A we compared the bolus dose of 1.2 mL vs. 2.4 mL and in Group B we compared the bolus dose of 2.4 mL vs. 4.8 mL (26 and 25 invasive carcinomas, respectively). CEUS was performed in real-time contrast harmonic imaging (CHI) using a L9-3 MHz probe. All examinations were recorded in a contrast side/side imaging mode loop for 120 s. Wash-in and wash-out patterns of the contrast agent were analyzed with advanced US quantification software and kinetic curves were used for statistical analysis. Results In Group B (2.4 mL vs. 4.8 mL), more and stronger correlation was found among kinetic parameters (area under the curve, P < 0.00001; lognormal model parameters, μ, P = 0.0007 and σ, P < 0.0001; mean transit time, P < 0.0001; model-based wash-out ratios, W21m, P = 0.0002; W50m, P = 0.0001; time-to-peak, P = 0.005) as compared to Group A (1.2 mL vs. 2.4 mL). Conclusion The optimal way to evaluate kinetic features of invasive breast tumors using real-time CEUS is with an injection of contrast agent of either 2.4 mL or 4.8 mL.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy