SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:prod.swepub.kib.ki.se:234642241"
 

Sökning: id:"swepub:oai:prod.swepub.kib.ki.se:234642241" > Transcatheter aorti...

Transcatheter aortic valve replacement using the iSleeve expandable sheath in small femoral arteries

Glaser, N (författare)
Karolinska Institutet
O'Sullivan, CJ (författare)
Saleh, N (författare)
Karolinska Institutet
visa fler...
Verouhis, D (författare)
Settergren, M (författare)
Karolinska Institutet
Linder, R (författare)
Karolinska Institutet
Rück, A (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2021-10-12
2021
Engelska.
Ingår i: Open heart. - : BMJ. - 2053-3624. ; 8:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Small femoral arteries have been associated with a higher risk of vascular complications in transfemoral transcatheter aortic valve replacement (TAVR). We investigated the feasibility and safety of TAVR in patients with small femoral arteries.MethodsIn this observational study, we included 82 patients who underwent transfemoral TAVR with the ACURATE neo system using the expandable 14F iSleeve sheath between 2018 and 2019 at Karolinska University Hospital, Sweden. Of these, 41 patients had a minimal femoral artery diameter of ≥5.5 mm (mean 6.5, range 5.5–9.2), and 41 patients had a minimal femoral artery diameter <5.5 mm (mean 4.9, range 3.9–5.4).ResultsThere was no significant difference in major vascular and bleeding complications between the small femoral artery group (7%) and the normal femoral artery group (2%) (p=0.62). The total of major and minor vascular complications did not differ significantly according to femoral artery size (17% vs 5%) (p=0.16). The iSleeve sheath was not correlated with any of the complications. The use of the iSleeve sheath was unsuccessful in four patients (5%), of which one patient had a small femoral artery diameter.ConclusionTransfemoral TAVR with the ACURATE neo system using the iSleeve sheath is a promising method for patients with small femoral arteries even though we found a trend towards higher rates of complications in these patients. The use of expandable sheaths may expand the spectrum of patients that can be treated with transfemoral TAVR, and thus may improve the prognosis in patients with severe aortic valve stenosis.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy