Sökning: id:"swepub:oai:research.chalmers.se:05922010-9fe6-4168-83cf-17fde71f4795" >
Shallow burial of d...
Shallow burial of district heating pipes
-
Sällberg, Sven-Erik (författare)
-
Forsaeus Nilsson, Stefan, 1972 (författare)
- 2008
- 2008
- Engelska.
-
Ingår i: The 11th International Symposium on District Heating and Cooling.
- Relaterad länk:
-
https://research.cha...
Abstract
Ämnesord
Stäng
- The aim with this paper was to study if the investment costs for district heating installations in suburban areas can be lowered with more rational construction work. A field trial was done with four twin pipes of dimension 2xDN32/160 laid between 600 mm and 180 mm below the asphalt surface in a road with heavy traffic. The conclusion is that shallow burial lowers the investment costs and is technically possible if the road structure is properly built.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Infrastrukturteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Infrastructure Engineering (hsv//eng)
Nyckelord
- district heating pipe
- polyurethane foam
- service temperature
- thermal life
- shallow burial
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)