SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:12d03104-25da-49bb-9621-a6f9b3362699"
 

Sökning: id:"swepub:oai:research.chalmers.se:12d03104-25da-49bb-9621-a6f9b3362699" > Towards an optimize...

Towards an optimized flow-sheet for a SANEX demonstration process using centrifugal contactors

Magnusson, Daniel, 1978 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Christiansen, B. (författare)
Europeiska kommissionens gemensamma forskningscentrum (JRC),Joint Research Centre (JRC), European Commission
Glatz, J. P. (författare)
Europeiska kommissionens gemensamma forskningscentrum (JRC),Joint Research Centre (JRC), European Commission
visa fler...
Malmbeck, R. (författare)
Europeiska kommissionens gemensamma forskningscentrum (JRC),Joint Research Centre (JRC), European Commission
Modolo, G. (författare)
Forschungszentrum Jülich GmbH
Serrano-Purroy, D. (författare)
Europeiska kommissionens gemensamma forskningscentrum (JRC),Joint Research Centre (JRC), European Commission
Sorel, C. (författare)
Le Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA),The French Alternative Energies and Atomic Energy Commission (CEA)
visa färre...
 (creator_code:org_t)
Walter de Gruyter GmbH, 2009
2009
Engelska.
Ingår i: Radiochimica Acta. - : Walter de Gruyter GmbH. - 0033-8230. ; 97:3, s. 155-159
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The design of an efficient process flow-sheet requires accurate extraction data for experimental set-up used. Often this data is provided as equilibrium data. Due to the small hold-up volume compared to the flow rate in centrifugal contactors the time for extraction is often too short to reach equilibrium D-ratios. In this work single stage kinetics experiments have been carried out to investigate the D-ratio dependence of the flow rate and to compare this with equilibrium batch experiments for a SANEX system based on CyMe4-BTBP. The first centrifuge experiment was run with spiked solutions while in the second a genuine actinide/lanthanide fraction from a TODGA process was used. Three different flow rates were tested with each set-up. the results show that even with low flow rates, only around 9% of the equilibrium D-ratio (Am) was reached for the extraction in the spiked test and around 16% in the hot test (the difference is due to the size of the centrifuges). In the hot test the lanthanide scrubbing was inefficient whereas in the stripping both the actinides and the lanthanides showed good results. Based on these results improvements of the suggested flow-sheet is discussed.

Nyckelord

minor actinides
CyMe4-BTBP
actinides
recovery
Extraction
Kinetics
Centrifugal contactor
Partitioning
Minor
current extraction process
diamex process

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy