Usability Evaluation of a GUI Prototype for a Ventilator Machine.

Liu, Yuanhua, 1971 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Osvalder, Anna-Lisa, 1961 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
Springer Science and Business Media LLC, 2005
2005
Engelska.
Ingår i: International Journal of Clinical Monitoring and Computing. - : Springer Science and Business Media LLC. - 0167-9945 .- 1387-1307 .- 1573-2614. ; 18:5-6, s. 365-372
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective. Information presentation on the monitor screen of ventilator machines affects nurses' response and decision-making during ventilation treatment. The purpose of this study is to evaluate whether a new GUI (graphical user interface) prototype, the so-called circular displayprototype can make deviations easy to detect. Method. A numerical display prototype was made and used as a reference displ ay in the evaluation. Six task scenarios that involved parameter changes were selected to simulate a real situation under volume control (VC) mode during ventilation treatment. Usability tests with the two display designs were carried out in a usability laboratory. Twenty medical nursing students participated as test subjects in the usability tests. Results. The objective results showed that the graphical circular display had an advantage over the numerical display in interpreting parameter changes, but not in reducing the error rates for detecting the number of parameter changes or for forming an overall picture of the patient's situation. Furthermore, the circular display prototype did not improve the detection time. Conclusions. Although the majority of the test subjects preferred the graphical circular display, the results implied that several aspects of this prototype should be improved in a future development study.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)
NATURVETENSKAP  -- Data- och informationsvetenskap -- Människa-datorinteraktion (hsv//swe)
NATURAL SCIENCES  -- Computer and Information Sciences -- Human Computer Interaction (hsv//eng)
NATURVETENSKAP  -- Data- och informationsvetenskap -- Datavetenskap (hsv//swe)
NATURAL SCIENCES  -- Computer and Information Sciences -- Computer Sciences (hsv//eng)

Nyckelord

Numerical display
Graphical circular display
Prototype
Usability tests
Deviation detection

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy