SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:1967fd0a-2e35-4458-b125-365d5e4681b4"
 

Sökning: id:"swepub:oai:research.chalmers.se:1967fd0a-2e35-4458-b125-365d5e4681b4" > Indoor humidity of ...

Indoor humidity of dwellings and association with building characteristics, behaviors and health in a northern climate

Psomas, Theofanis, 1983 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Teli, Despoina, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Langer, Sarka, 1960 (författare)
IVL Svenska Miljöinstitutet AB,IVL Swedish Environmental Research Institute,Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Wahlgren, Paula, 1967 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Wargocki, Pawel (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
visa färre...
 (creator_code:org_t)
Elsevier BV, 2021
2021
Engelska.
Ingår i: Building and Environment. - : Elsevier BV. - 0360-1323 .- 1873-684X. ; 198
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Data from a nationwide survey on the status of the Swedish residential building stock and indoor air quality was placed in the public domain by the National Board of Housing, Building and Planning of Sweden. The current research investigates the indoor humidity conditions in Swedish residential buildings, single-family houses and apartments, assessing the measurements from the extensive BETSI-survey against adjusted relative humidity levels based on existing norms and Standards. The aim of this study is to investigate associations and correlations between relative humidity levels and multiple building and system characteristics, occupancy patterns and behaviors and health symptoms-complaints. The analysis uses 13 categorical and 9 continuous variables-parameters of the examined dwellings. Analysis shows that low indoor relative humidity is a realistic issue in Swedish dwellings during the heating season. The issue is more prevalent in apartments than single-family houses. In addition, low indoor relative humidity seems to be more extensive in dwellings with higher indoor temperature, smaller volume, higher ventilation rate and frequent airing practices, lower number of occupants, constructed mainly after 1985, in city suburbs and in the northern parts of the country. The developed multinomial logistic regression model may predict very accurately the relative humidity level of the Swedish dwellings, during heating season. This analysis offers additional evidence to the scientific literature for possible correlation of low relative humidity with specific health symptoms, complaints and disturbances.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Miljöanalys och bygginformationsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Environmental Analysis and Construction Information Technology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Nyckelord

Ventilation
Air quality
Residential building
Symptom
Relative humidity
Dry air
Complaint
Sustainable urban planning

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy