SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:374a5df2-47fc-4c5c-a420-f203b23cfbcd"
 

Sökning: id:"swepub:oai:research.chalmers.se:374a5df2-47fc-4c5c-a420-f203b23cfbcd" > Performance evaluat...

Performance evaluation of hollow fiber air gap membrane distillation module with multiple cooling channels

Aryapratama, Rio (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Koo, H. (författare)
Korea Institute of Science and Technology (KITECH),University of Science and Technology (UST)
Jeong, S. (författare)
Korea Institute of Science and Technology (KITECH)
visa fler...
Lee, SangWook (författare)
Korea Institute of Science and Technology (KITECH),University of Science and Technology (UST)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2016
2016
Engelska.
Ingår i: Desalination. - : Elsevier BV. - 0011-9164. ; 385, s. 58-68
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The hollow fiber air gap membrane distillation (AGMD) module equipped with the multiple cooling channels network made of stainless steel was developed. The performance of the developed AGMD module was evaluated by conducting several experiments, including the effect of feed temperature and flow rate, ratio of membrane surface area to condensation surface area, membrane packing position, comparison with hollow fiber DCMD, and the effect of inner and outer module channels to process performance. Moreover, theoretical model was suggested for the multiple cooling channels module. This study reveals that the produced flux and thermal efficiency of this module were up to 12.5 kg/m2 h and 81.7%, respectively, which is higher than most of previous studies that used polymeric fibers as coolant channels. Furthermore, the optimum ratio of membrane area to condensation surface area to produce optimum flux and thermal efficiency is known to be around 0.55. Further experimental results show that the outer channel has significant contribution in reducing the amount of heat loss. This is also could be the reason why the average flux of hollow fiber AGMD module was only 22% lower, while the average thermal efficiency is 58% higher than that of hollow fiber DCMD module.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)

Nyckelord

Hollow fiber AGMD
Multiple cooling channels
Thermal efficiency
Modeling
Condensation surface area

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Aryapratama, Rio
Koo, H.
Jeong, S.
Lee, SangWook
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Naturresurstekni ...
och Energisystem
Artiklar i publikationen
Desalination
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy